3.6.3 Alarm Output Port
2 ways relay alarm output (NO contact). Provide external power to external alarm device.
To avoid overloading, please read the following relay parameters sheet carefully.
RS485 A/B cable is for the A/B cable of the PTZ decoder.
Relay Specification
Model: HFD23
Contact
Parameter
Contact mode 1Z
Contact resistance 100m(0.1A 6VDC)
Contact material AgNi+gold-plating
Contact 0.5A 125VAC/1A 30VDC
Max switch voltage 125VAC / 60VDC
Max switch current 2A
Max switch power 62.5VA/30W
Min allowed load 1mA 5V
Mechanical durability 1x10
7
(300/min)
Electric durability 1x10
5
(30/min)
Performance
Parameter
Insulation resistance 1000M(500VDC)
Media
pressure
Between
loop and
contract
1000VAC 1min
Between
separated
contact
400VAC 1min
Operation time (Rated
voltage)
5ms
Release time (Rated
voltage)
5ms
Bound time (Rated
voltage)
About 5ms
Loop temperature
rise(Rated voltage)
65K
Strike 98m/s2
Vibration 10Hz~55 Hz 3.3mm Double amplitude
Humidity 98% RH, 40
Temperature -30 ~70
Weight About 2.2g
leading-out end mode
DIP