Datasheet

iC-MA
8-BIT ANGULAR HALL SENSOR / ENCODER
Rev C1, Page 18/19
VDD
iC-MA
GND
CFG1 NCLUP
NCLDN
NCLR
NERR
RESET
OUTPUT
DATA INPUT
P0 P0
Q0 Q0
CPU CPU
CPD CPD
NPL NPL
TCU TCU
TCD TCD
MR MR
P1 P1
Q1 Q1
P2 P2
74HCT193 74HCT193
Q2 Q2
P3 P3
Q3 Q3
CFG2
CFG3
NEN
Figure 16: iC-MA with binary counter
DIR-INC Mode
In DIR-INC mode a change in angle for both directions
of rotation generates an output pulse for signal CLK
(pin A). Signal DIR (pin B) gives the direction of ro-
tation. This mode permits the operation of external
binary counter modules (such as 74HC/HCT191, for
example), with signal NCLR (pin C) being used to re-
set the external counter. With a rising edge at CLK
the counter status is counted up or down, depending
on the value of the DIR signal. A low level at DIR trig-
gers a countup; a high level causes the setup to count
down. Figure 17 shows a countup sequence followed
by a countdown sequence, both across the zero posi-
tion.
Time [us]
CLK
DIR
N
CLR
Figure 17: DIR-INC mode
REVISION HISTORY
Rel Rel.Date Chapter Modification Page
A1 05-01-21 All Initial release All
Rel Rel.Date Chapter Modification Page
A2 06-05-10 ELECTRICAL CHARACTERISTICS Items and drawings updated
Rel Rel.Date Chapter Modification Page
B1 06-07-20 ELECTRICAL CHARACTERISTICS Item 404 max.: 750 k, Item 704 min.: 5 µA 4, 5
Rel Rel.Date Chapter Modification Page
B2 07-07-02 PACKAGING INFORMATION Backside paddle complemented 3
Rel Rel.Date Chapter Modification Page
B3 09-07-09 ELECTRICAL CHARACTERISTICS Item 106 conditions: using magnet with 4mm diameter
Item 201 conditions: on output, with external magnetic field amplitude of 20 kA/m
5
Rel Rel.Date Chapter Modification Page
C1 14-10-28 All package Figures updated 1, 3, 4
CONTENTS, REVISION HISTORY Chapter introduced 2, 18
ELECTRICAL CHARACTERISTICS Item 503 max.: 300 mV 6
iC-Haus expressly reserves the right to change its products and/or specifications. An info letter gives details as to any amendments and additions made to the
relevant current specifications on our internet website www.ichaus.com/infoletter; this letter is generated automatically and shall be sent to registered users by
email.
Copying even as an excerpt is only permitted with iC-Haus’ approval in writing and precise reference to source.
iC-Haus does not warrant the accuracy, completeness or timeliness of the specification and does not assume liability for any errors or omissions in these
materials.
The data specified is intended solely for the purpose of product description. No representations or warranties, either express or implied, of merchantability, fitness
for a particular purpose or of any other nature are made hereunder with respect to information/specification or the products to which information refers and no
guarantee with respect to compliance to the intended use is given. In particular, this also applies to the stated possible applications or areas of applications of
the product.
iC-Haus products are not designed for and must not be used in connection with any applications where the failure of such products would reasonably be expected
to result in significant personal injury or death (Safety-Critical Applications) without iC-Haus’ specific written consent. Safety-Critical Applications include, without
limitation, life support devices and systems. iC-Haus products are not designed nor intended for use in military or aerospace applications or environments or in
automotive applications unless specifically designated for such use by iC-Haus.
iC-Haus conveys no patent, copyright, mask work right or other trade mark right to this product. iC-Haus assumes no liability for any patent and/or other trade
mark rights of a third party resulting from processing or handling of the product and/or any other use of the product.