Server User Manual

Features Min # Max # Max Increments
Purchase
Features Features Connections per Feature Increments
16-port 0
(1)
32
480 channels
16 channels 4 channels
ESCON 1reserved as
as a spare
FICON 0
(1)
32 64/128* 2/4*
2/4*
Express4* channels channels channels
FICON 0
(1)
20
80 channels
4
channels
4 channels
Express2
**
FICON 0
(1)
20
40 channels
2
channels
2 channels
Express
**
ICB-4 0
(1)
6
12 links
(2) (3)
2
links
1 link
ISC-3 0
(1)
12
48 links
(2)
4
links
1 link
1x PSIFB 0
(1)
6
12 links
(2)
2
links
2 links
12x PSIFB 0
(1)
6
12 links
(2) (3)
2
links
2 links
OSA- 0 24 48/96* 2 or 4
2 ports/
Express3* ports 4 ports
OSA- 0 24 24/48 1 or 2
2 ports/
Express2
**
ports 1 port
Crypto 0 8 8/16 PCI-X 1/2* PCI-X
2* PCI-X
Express2
*
adapters adapters adapters
(4)
1) Minimum of one I/O feature (ESCON, FICON) or Coupling Link (PSIFB,
ICB-4, ISC-3) required.
2) The maximum number of external Coupling Links combined cannot
exceed 56 per server. There is a maximum of 64 coupling link CHPIDs
per server (ICs, ICB-4s, active ISC-3 links, and IFBs)
3) ICB-4 and 12x IB-DDR are not included in the maximum feature count for
I/O slots but are included in the CHPID count.
4) Initial order of Crypto Express2 is 2/4 PCI-X adapters (two features).
Each PCI-X adapter can be confi gured as a coprocessor or an accelera-
tor.
* FICON Express4-2C 4KM LX has two channels per feature, OSA-
Express3 GbE and 1000BASE-T have 2 and 4 port options and Crypto
Express2-1P has 1 coprocessor
** Available only when carried forward on an upgrade from z890 or or z9
BC. Limited availability for OSA-Express2 GbE features.
z10 BC Concurrent PU Conversions
Must order (characterize one PU as) a CP, an ICF or an
IFL
Concurrent model upgrade is supported
Concurrent processor upgrade is supported if PUs are
available
Add CP, IFL, unassigned IFL, ICF, zAAP, zIIP or
optional SAP
PU Conversions
Standard SAP cannot be converted to other PU types
To CP IFL Unassigned ICF
zAAP
zIIP Optional
From IFL SAP
CP X Yes
Yes Yes
Yes Yes Yes
IFL Yes X
Yes Yes
Yes Yes Yes
Unassigned Yes Yes
X Yes
Yes Yes Yes
IFL
ICF Yes Yes
Yes X
Yes Yes Yes
zAAP Yes Yes
Yes Yes
X Yes Yes
zIIP Yes Yes
Yes Yes
Yes X Yes
Optional Yes Yes
Yes Yes
Yes Yes X
SAP
Exceptions: Disruptive if ALL current PUs are converted to different types
may require individual LPAR disruption if dedicated PUs are converted.
62