Operation Manual
Note: See Chapter 7, “Parts listing, Types 8861, 8862,” on page 139 to determine which components are
replaceable by the customer and which components must be replaced by an IBM field service technician.
No beep symptom FRU/action
System will not power-up
(Power supply ac LED is on)
v See “Power LED errors” on page 130.
POST error codes
In the following error codes, X can be any number or letter.
Note: See Chapter 7, “Parts listing, Types 8861, 8862,” on page 139 to determine which components are
replaceable by the customer and which components must be replaced by an IBM field service technician.
Error code/symptom FRU/action
062 (Three consecutive boot failures using the
default configuration.)
1. Flash system to latest level.
2. I/O board.
101, 102 (Tick timer internal interrupt, internal
timer channel 2)
v I/O board
106 (Diskette controller failure)
v I/O board
114 (Adapter read-only memory (ROM) error)
1. Remove adapters and reinstall one at a time; replace failing
adapter.
2. I/O board.
151 (Real time clock error)
1. Battery
2. I/O board
161 (Real time clock battery error)
1. Battery
2. I/O board
162 (Device Configuration Error)
Note: Be sure to load the default settings and
any additional desired settings; then, save the
configuration
1. Run Configuration/Setup
2. Battery
3. Failing device
4. I/O board
163 (Real-Time Clock error)
1. Run Configuration/Setup.
2. Battery.
3. I/O board.
175 (Hardware error)
1. I/O board
2. Service processor
177, 178 (Security hardware error)
1. Run Configuration/Setup.
2. I/O board.
3. Service processor.
184 (Power-on password corrupted)
1. Run Configuration/Setup.
2. Battery.
3. I/O board.
186 (Security hardware control logic failed)
1. Run Configuration/Setup.
2. I/O board.
3. Service processor.
88 IBM xSeries 365 Types 8861, 8862: Hardware Maintenance Manual and Troubleshooting Guide