Operation Manual
7. POST starts. Select 1 - Update POST/BIOS from the menu that contains
various flash (update) options.
8. When you are asked whether you want to move the current POST/BIOS image
to the backup ROM location, type N.
Attention: Typing Y will copy the damaged BIOS code into the secondary
page.
9. When you are asked whether you would like to save the current code to a
diskette, select N.
10. Type 1 and press Enter to continue.
Attention: Do not restart or power off the server until the update is
completed.
11. Turn off the server.
12. Move jumper J19 back to pins 1 and 2 to return to normal startup mode.
13. Replace the cover; then, restart the server.
Password override jumper
Change the position of the password override jumper by using the following
procedure:
1. Read “Safety information” on page 147 and “Handling static-sensitive devices”
on page 30.
2. Turn off the server and peripheral devices and disconnect all external cables
and power cords; then, remove the cover.
3 2 1
1 2 3
1 2 3
1 2 3
IXA voltage
jumper (J26)
Disable Wake on LAN
jumper (J24)
Power-on password override
jumper (J20)
Boot recovery (BIOS)
jumper (J19)
3. Locate the power-on password override jumper (J20), removing any
components that impede access to the jumper.
Note: You might have to remove the Remote Supervisor Adapter II to access
the jumper.
4. Move the jumper from pins 1 and 2 (default) to pins 2 and 3.
Chapter 3. Diagnostics 25