Operation Manual

Note: See Chapter 7, “Parts listing, Types 8861, 8862,” on page 139 to determine which components are
replaceable by the customer and which components must be replaced by an IBM field service technician.
Service Processor message FRU/action
5V Planar Fault
v I/O board assembly
Application Posted Alert to ASM
v Information only
Cable: Media cable not detected
1. Verify IDE media cable is properly connected.
2. Media interposer card.
Cable: SCSI I2C cable not detected
1. Verify SCSI cables are properly connected.
2. SCSI backplane.
Continuous 3.3V over recommended value
v I/O board assembly
Continuous 3.3V under recommended value
v I/O board assembly
CPU X Over Temperature
1. Check all fans and remove any obstacles from the path of
airflow.
2. Verify room temperature is within recommended range.
3. Verify microprocessor heat sinks are properly seated.
DASD X over recommended temperature
1. Check all fans and remove any obstacles from the path of
airflow.
2. Verify room temperature is within recommended range.
Environmental Monitor firmware needs
updating. No environmental information
currently available.
v Run the latest version of the Remote Supervisor Adapter
Firmware Update Utility.
Environmental Monitor Flash Update Failed
v Run the latest version of the Remote Supervisor Adapter
Firmware Update Utility.
Environmental Monitor not responding
1. Run the latest version of the Remote Supervisor Adapter
Firmware Update Utility.
2. Replace appropriate board.
Environmental Monitor RAM Error
1. Run the latest version of the Remote Supervisor Adapter
Firmware Update Utility
2. Replace appropriate board.
Environmental Monitor ROM Error
1. Run the latest version of the Remote Supervisor Adapter
Firmware Update Utility
2. Replace appropriate board.
Ethernet Data Rate modified from <value1>
to <value2> by user <USERID>
v Information only
Ethernet Duplex setting modified from
<value1> to <value1> by user <USERID>
v Information only
Ethernet interface <value> by user <USERID>
v Information only
Ethernet locally administered MAC address
modified from x:x:x:x:x:x
v Information only
Ethernet MTU setting modified from x to y by
user <USERID>
v Information only
Failure reading I2C device. Check devices on
bus X
v Run diagnostics.
110 IBM xSeries 365 Types 8861, 8862: Hardware Maintenance Manual and Troubleshooting Guide