Operation Manual

Note: See Chapter 7, “Parts listing, Types 8861, 8862,” on page 139 to determine which components are
replaceable by the customer and which components must be replaced by an IBM field service technician.
Error code/symptom FRU/action
035-xxx-cnn (Check System error Log
before replacing a FRU. c = ServeRAID
channel number, nn = SCSI ID of failing
fixed disk drive.)
v Hard disk drive on channel C, SCSI ID nn
035-xxx-snn (Check System Error Log
before replacing a FRU. nn = SCSI ID of
failing fixed disk.)
v SCSI disk with ID nn on adapter in slot s
075-xxx-000 (Failed power supply test)
1. Power supply
2. Power backplane
089-xxx-001 (Failed Microprocessor test)
1. Microprocessor 1
2. Microprocessor tray assembly
089-xxx-002 (Failed Optional
Microprocessor test)
1. Microprocessor 2
2. Microprocessor tray assembly
089-xxx-003 (Failed Microprocessor test)
1. Microprocessor 3
2. VRM 3
3. Microprocessor tray assembly
089-xxx-004 (Failed Microprocessor test)
1. Microprocessor 4
2. VRM 4
3. Microprocessor tray assembly
091-09x-041 (RXE Expansion Port failure;
valid only with RXE cable) (where x of 4 =
cable or initialization error; x of 5 =
transmit error; x of 6 = receive error; x of 7
= ping error, below threshold)
1. RXE cable
2. I/O board
091-09x-056 (RXE100 Side A Port failure)
(where x of 4 = cable or initialization error;
x of 5 = transmit error; x of 6 = receive
error; x of 7 = ping error, below threshold)
1. RXE cable
2. RXE Expansion board to which cable is connected (Side A or Side
B)
3. I/O board
091-09x-057 (RXE100, from Side A to
Side B failure) (where x of 4 = cable or
initialization error; x of 5 = transmit error; x
of 6 = receive error; x of 7 = ping error,
below threshold)
1. Side A card in RXE100
2. Side B card in RXE100
091-09x-058 (RXE100 Side B Port failure)
(where x of 4 = cable or initialization error;
x of 5 = transmit error; x of 6 = receive
error; x of 7 = ping error, below threshold)
1. RXE cable
2. RXE Expansion board to which cable is connected (Side A or Side
B)
3. I/O board
091-09x-059 (RXE100, from Side B to
Side A failure) (where x of 4 = cable or
initialization error; x of 5 = transmit error; x
of 6 = receive error; x of 7 = ping error,
below threshold)
1. Side B card in RXE100
2. Side A card in RXE100
155-xxx-xxx (Failed Active Memory
latch
test)
1. Memory cassette cover assembly
2. Memory cassette
Chapter 6. Symptom-to-FRU index 97