Desktop Computer Hardware Maintenance Manual
POST  Error  Code  FRU/Action 
10101,  10102,  10104,  10105,  10106,  10107, 
10108,  10109,  10111, 
10112,  10113,  10114, 
10115,  10116 
1.  Have  customer  verify  correct  operating 
system  device  drivers  are  installed  and 
operational. 
2.  Modem 
10103,  10110,  101171 
1.  System  Board 
2.  Data/Fax  Modem 
3.  Riser  card 
10117 
Not  listed  above 
1.  Check  system  speaker 
2.  Check  PSTN  cable 
3.  External  DAA 
(if  installed) 
4.  Modem 
10118 
1.  Run  Diagnostics  and  verify  the  correct 
operation  of  the  modem  slot 
2.  Modem 
10119 
1.  Diagnostics  detected  a  non-IBM  modem 
2.  Modem 
10120 
1.  Check  PSTN  Cable 
2.  External  DAA 
(if  installed) 
3.  Modem 
10132,  10133,  10134, 
10135,  10136,  10137, 
10138,  10139,  10140, 
10141,  10142,  10143, 
10144,  10145,  10146, 
10147,  10148,  10149, 
10150,  10151,  10152 
1.  Modem 
10153 
1.  Data/Fax  Modem 
2.  System  Board 
3.  Riser  card 
101XX 
Not  listed  above 
1.  Modem  Adapter/A 
2.  Data/Fax  Modem 
3.  System  Board 
4.  Riser  card 
10450,  10451,  10490, 
10491,  10492,  10499 
Read/write  error 
1.  Run  Enhanced  Diagnostics 
2.  Hard  Disk  Drive 
3.  System  Board 
4.  Riser  card 
10452 
Seek  test  error 
1.  Run  Enhanced  Diagnostics 
10453 
Wrong  drive  type? 
Information  only 
10454 
Sector  buffer  test  error 
1.  Run  Enhanced  Diagnostics 
Chapter  7.  Symptom-to-FRU  Index  81