Desktop Computer Hardware Maintenance Manual
POST  Error  Code  FRU/Action 
1804  PCI/PnP  Error!  Not  Enough  Real 
Memory  Space  Available 
1.  Run  Setup  and  verify  PCI/ISA 
configuration  settings. 
2.  If  necessary,  set  ISA  adapters  to  Not 
available  to  allow  PCI  adapters  to 
properly  configure. 
3.  Remove  any  suspect  ISA  adapters. 
4.  Rerun  diagnostics. 
5.  PCI  Adapter 
1805  PCI/PnP  Error!  Adapter  ROM 
Checksum  Error 
1.  Run  Setup  and  verify  PCI/ISA 
configuration  settings. 
2.  Rerun  diagnostics. 
3.  PCI  Adapter 
180X,  188X 
PCI  configuration  or  resource  error 
1.  Run  Setup  and  verify  PCI/ISA 
configuration  settings. 
2.  Rerun  diagnostics. 
3.  PCI  Adapter 
1962 
No  operating  system  found 
1.  Press  F1  to  repeat  boot  sequence. 
209X 
1.  Diskette  Drive 
2.  Diskette  Cable 
20XX 
Not  listed  above 
1.  BSC  Adapter 
21XX 
1.  SCSI  Device 
2.  16-bit  AT  Fast  SCSU  adapter 
3.  Alternate  BSC  adapter 
2401,  2402 
If  screen  colors  change 
1.  Display 
2401,  2402 
If  screen  colors  are  OK 
1.  System  Board 
2.  Display 
2409 
1.  Display 
2410 
1.  System  Board 
2.  Display 
2462 
Video  memory  configuration  error 
1.  Check  cable  connections 
2.  Run  Setup  and  verify  video 
configuration  settings 
3.  Video  Memory  Modules 
4.  Video  Adapter  (if  installed) 
5.  System  Board 
4611,  4630 
1.  Multiport/2  Interface  Board 
2.  Multiport/2  Adapter 
4612,  4613,  4640,  4641 
1.  Memory  Module  Package 
2.  Multiport/2  Adapter 
4650 
1.  Multiport/2  Interface  Cable 
Chapter  7.  Symptom-to-FRU  Index  79