Desktop Computer Hardware Maintenance Manual
Diagnostic  Error  Code  FRU/Action 
020-197-XXX 
PCI  test  warning 
1.  Make  sure  the  component  that  is  called 
out  is  connected  and/or  enabled.  See 
Chapter  5,  “Using  the  IBM  Setup 
Utility,”  on  page  19 
2.  Re-run  test 
3.  Replace  the  component  that  is  called  out 
in  warning  statement 
4.  Replace  the  component  under  test 
020-198-XXX 
PCI  test  aborted 
1.  If  a  component  is  called  out,  make  sure 
it  is  connected  and/or  enabled.  See 
Chapter  5,  “Using  the  IBM  Setup 
Utility,”  on  page  19 
2.  Flash  the  system  and  re-test.  See  “Flash 
update  procedures”  on  page  148 
3.  Go  to  “Undetermined  problems”  on  page 
89 
020-199-XXX 
PCI  test  failed,  cause  unknown 
1.  Go  to  “Undetermined  problems”  on  page 
89 
2.  Flash  the  system  and  re-test.  See  “Flash 
update  procedures”  on  page  148 
3.  Replace  component  under  function  test 
020-262-XXX
PCI  system  error 
1.  PCI  card 
2.  Riser  card,  if  installed 
3.  System  board 
025-000-XXX
IDE
  interface  Test  Passed 
1.  No  action 
025-00X-XXX 
025-01X-XXX 
IDE  interface  failure 
1.  IDE  signal  cable 
2.  Check  power  supply  voltages 
3.  Reseat  IDE  signal  cable 
4.  IDE  device 
5.  System  board 
025-027-XXX 
IDE  interface  Configuration/Setup  error 
1.  IDE  signal  cable 
2.  Flash  the  system.  See  “Flash  update 
procedures”  on  page  148 
3.  Reseat  IDE  signal  cable 
4.  IDE  device 
5.  System  board 
025-02X-XXX 
025-03X-XXX 
025-04X-XXX 
IDE  Interface  failure 
1.  IDE  signal  cable 
2.  Check  power  supply 
3.  Reseat  IDE  signal  cable 
4.  IDE  device 
5.  System  board 
025-195-XXX 
IDE  interface  Test  aborted  by  user 
1.  Information 
2.  Re-start  the  test,  if  necessary 
025-196-XXX 
IDE  interface  test  halt,  error  threshold 
exceeded 
1.  Press  F3  to  review  the  log  file 
2.  Re-start  the  test  to  reset  the  log  file 
60  Hardware  Maintenance  Manual