Diagnostic  Error  Code  FRU/Action 
005-2XX-XXX 
005-3XX-XXX 
Video  subsystem  error 
1.  Video  card,  if  installed 
2.  System  board 
006-000-XXX 
Diskette  interface  Test  Passed 
1.  No  action 
006-0XX-XXX 
Diskette  interface  error 
1.  Diskette  drive  Cable 
2.  Diskette  drive 
3.  System  board 
006-195-XXX 
Diskette  interface  Test  aborted  by  user 
1.  Information 
2.  Re-start  the  test,  if  necessary 
006-196-XXX 
Diskette  interface  test  halt,  error  threshold 
exceeded 
1.  Press  F3  to  review  the  log  file 
2.  Re-start  the  test  to  reset  the  log  file 
006-197-XXX 
Diskette  interface  test  warning 
1.  If  a  component  is  called  out,  make  sure 
it  is  connected  and/or  enabled 
2.  Re-run  test 
3.  Replace  the  component  that  is  called  out 
in  warning  statement 
4.  Replace  the  component  under  test 
006-198-XXX 
Diskette  interface  test  aborted 
1.  If  a  component  is  called  out,  make  sure 
it  is  connected  and/or  enabled 
2.  Flash  the  system  and  re-test.  See  “Flash 
update  procedures”  on  page  148 
3.  Go  to  “Undetermined  problems”  on  page 
89 
006-199-XXX 
Diskette  interface  test  failed,  cause  unknown 
1.  Go  to  “Undetermined  problems”  on  page 
89 
2.  Flash  the  system  and  re-test 
3.  Replace  component  under  function  test 
006-25X-XXX 
Diskette  interface  Error 
1.  Diskette  drive  cable 
2.  Diskette  drive 
3.  System  board 
011-000-XXX 
Serial  port  Interface  Test  Passed 
1.  No  action 
011-001-XXX 
Serial  port  Presence 
1.  Remove  external  serial  device,  if 
present 
2.  Run  setup,  enable  port 
3.  System  board 
011-002-XXX 
011-003-XXX 
Serial  port  Timeout/Parity  error 
1.  System  board 
011-013-XXX 
011-014-XXX 
Serial  port  Control  Signal/Loopback  test 
failure 
1.  System  board 
011-015-XXX 
Serial  port  External  Loopback  failure 
1.  Wrap  plug 
2.  System  board 
Chapter  7.  Symptom-to-FRU  Index  55