Desktop Computer Hardware Maintenance Manual
POST  Error  Code  FRU/Action 
178 
1.  System  Board 
179  Boot  Integrity  Services  Segment  Error 
1.  System  Board 
183 
1.  Enter  the  administrator  password 
184 
Asset  Control  Antenna  not  detected 
1.  Make  sure  Asset  Care  and  Asset  ID
™
are  enabled  in  Configuration/Setup 
2.  RFID  Antenna 
3.  System  Board 
185 
Corrupted  boot  sequence 
1.  Set  configuration  and  reinstall  the  boot 
sequence 
186  Security  Hardware  Control  Logic  Error 
1.  System  Board 
187 
1.  Clear  Administration  password 
2.  System  Board 
189 
1.  More  than  three  password  attempts 
were  made  to  access  the  computer 
190 
System  Security:  Invalid  Remote  Change 
Requested 
1.  System  Board 
191  System  Security:  IBM  Embedded 
Security  Hardware  Reset 
1.  System  Board 
193  System  Security:  IBM  Embedded 
Security  Hardware  Removed 
1.  System  Board 
194  System  Security:  Asset  ID  Antenna  has 
been  Removed 
1.  System  Board 
195  System  Security:  Asset  ID  Antenna  has 
been  Installed 
1.  System  Board 
196  System  Tampered  Cleared 
1.  System  Board 
1XX 
Not  listed  above 
1.  System  Board 
201,  20X 
Memory  data  error 
1.  Run  Enhanced  Diagnostics  Memory 
Test 
2.  Memory  Module 
3.  System  Board 
225 
1.  Unsupported  Memory 
229 
External  cache  test  error 
1.  L2  Cache  Memory 
2.  System  Board 
262 
POST  detected  a  base  memory  or  extended 
memory  type  error 
1.  Run  Setup.  Check  System  Summary 
menu  for  memory.  (See  “Starting  the 
IBM  Setup  Utility  program”  on  page 
19.) 
2.  Run  the  Extended  Memory  Diagnostic 
tests. 
301  Keyboard  Error 
1.  Keyboard 
2.  Keyboard  Cable 
3.  System  Board 
Chapter  7.  Symptom-to-FRU  Index  75