Desktop Computer Hardware Maintenance Manual
POST  Error  Code  FRU/Action 
135  Fan  failure 
1.  Fan 
2.  System  board 
151 
System  board  failure 
1.  System  Board 
161 
Bad  CMOS  battery 
1.  Run  Setup 
2.  CMOS  Backup  Battery  (see  “Replacing 
the  battery”  on  page  31) 
3.  System  Board 
162 
Configuration  mismatch 
1.  Run  Setup  and  verify  Configuration 
2.  Had  a  device  been  added,  removed, 
changed  location?  If  not,  suspect  that 
device. 
3.  Power-on  external  devices  first,  then 
power-on  computer 
4.  CMOS  Backup  Battery  (see  “Replacing 
the  battery”  on  page  31)System  Board 
5.  System  Board 
163 
Date  and  Time  Incorrect 
1.  Time  and  Date  Set 
2.  CMOS  Backup  Battery  (see  “Replacing 
the  battery”  on  page  31) 
3.  System  Board 
164 
Memory  Size  Error 
1.  Run  Setup.  Check  System  Summary 
menu  for  memory  size  change.  (See 
“Starting  the  IBM  Setup  Utility 
program”  on  page  19.) 
2.  Run  the  Extended  Memory  Diagnostic 
tests 
166 
Boot  Block  Check  Sum  Error 
1.  Run  Flash  Recovery  using  Boot  Block. 
See  “Recovering  from  a  POST/BIOS 
update  failure”  on  page  148. 
2.  System  Board 
167 
No  Processor  BIOS  Update  Found 
1.  Run  Setup.  Check  Stepping  level  for 
the  BIOS  level  needed,  then  perform 
the  flash  update. 
2.  Processor 
168
Alert  on  LA
™
N  error 
1.  Run  Setup.  Check  to  see  that  Ethernet 
and  Alert  on  LAN  are  enabled. 
2.  System  Board 
17X,  18X 
1.  C2  Security 
175  Primary  Copy  of  Secure  Data  is 
damaged 
1.  Run  the  IBM  Setup  Utility  program. 
See  “Starting  the  IBM  Setup  Utility 
program”  on  page  19.. 
2.  System  Board 
176  The  System  has  been  tampered  with 
1.  Covers  were  removed  from  the 
computer 
177 
Corrupted  Administrator  Password 
1.  System  Board 
74  Hardware  Maintenance  Manual