Design to ASHRAE Class A3, ambient of 36 °C to 40 °C (96.8 °F to 104 °F), with relaxed support:
Supports cloud-like workload with no performance degradation acceptable (Turbo-Off).
Under no circumstance can any combination of worst-case workload and configuration result in
system shutdown or design exposure at 40 °C.
The worst-case workload (like Linpack, Turbo-On) might have performance degradation.
Electrical:
Models with 900 W AC power supplies:
100 to 127 (nominal) V ac; 50 Hz or 60 Hz; 10.3 A
200 to 240 (nominal) V ac; 50 Hz or 60 Hz; 5.0 A
Input kilovolt-amperes (kVA) (approximately):
Minimum configuration: 0.15 kVA
Maximum configuration: 1.194 kVA
Models with 750 W Platinum AC power supplies:
100 to 127 (nominal) V ac; 50 Hz or 60 Hz; 8.6 A
200 to 240 (nominal) V ac; 50 Hz or 60 Hz; 4.2 A
Input kilovolt-amperes (kVA) (approximately):
Minimum configuration: 0.15 kVA
Maximum configuration: 1.015 kVA
Models with 750 W Titanium AC power supplies:
200 to 240 (nominal) V ac; 50 Hz or 60 Hz; 4.2 A
Input kilovolt-amperes (kVA) (approximately):
Minimum configuration: 0.15 kVA
Maximum configuration: 0.965 kVA
Models with 550 W AC power supplies:
100 to 127 (nominal) V ac; 50 Hz or 60 Hz; 6.5 A
200 to 240 (nominal) V ac; 50 Hz or 60 Hz; 3.3 A
Input kilovolt-amperes (kVA) (approximately):
Minimum configuration: 0.16 kVA
Maximum configuration: 0.732 kVA
BTU output:
Minimum configuration: 525 Btu/hr (154 watts)
Maximum configuration: 4064 Btu/hr (1191 watts)
Noise level:
6.6 bels (operating)
6.4 bels (idle)