Switch User Manual

This soft copy for use by IBM employees only.
ocPowerOutputWattageAvailable OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
In hundredths of a Watt (1/100 Watt), the wattage
available to power-up modules. If power fault-tolerant
mode is enabled (when it was previously disabled), this
objects value is decreased by the amount of power reserved
for the voltage line. If power fault-tolerant mode is
disabled (when it was previously enabled), this object s
value is increased by the amount of power that is returned
to the available power budget for the voltage line.
::= { ocPowerOutputEntry 5 }
ocPowerOutputUnmanagedWattageAlloc OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
In hundredths of a Watt (1/100 Watt), the wattage
reserved for modules that are not power-manageable.
This value 0 is always returned.
::= { ocPowerOutputEntry 6 }
--
-- Module power configuration
--
ocPowerSlotTable OBJECT-TYPE
SYNTAX SEQUENCE OF OcPowerSlotEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
A table that contains power management information
for each non-empty, payload slot in the hub. Note
that for multi-slot IBM 8260 modules, there is one point
of power management contact and control. Hence, only
the leftmost slot is represented in this table.
::= { ocPower 3 }
ocPowerSlotEntry OBJECT-TYPE
SYNTAX OcPowerSlotEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
A list of power management information for each
payload slot in the hub containing an 8260 module.
INDEX { ocPowerSlotIndex }
::= { ocPowerSlotTable 1 }
OcPowerSlotEntry ::=
SEQUENCE {
ocPowerSlotIndex
INTEGER,
ocPowerSlotClass
INTEGER,
ocPowerSlotAdminStatus
INTEGER,
268 ATM Workgroup Solutions: Implementing the 8285 ATM Switch