IBM TotalStorage DR550 SMB Version 1.
IBM TotalStorage DR550 SMB Version 1.0 ------ 27 May 2005 Page 2 Table of Contents INTRODUCTION............................................................................................................. 5 HARDWARE OVERVIEW............................................................................................... 6 IBM eServer P5 520 ..................................................................................................................................................6 Management Console..
IBM TotalStorage DR550 SMB Version 1.0 ------ 27 May 2005 Page 3 Cabling to the customer’s Ethernet / IP Network ...........................................................................................17 Setting up the Management Console ................................................................................................................19 Changing Server Names ..................................................................................................................................
IBM TotalStorage DR550 SMB Version 1.0 ------ 27 May 2005 Page 4 Support Web Site....................................................................................................................................................44 LEGAL NOTICES ......................................................................................................... 45 REFERENCES.............................................................................................................. 46 UPDATES TO THIS GUIDE...........
IBM TotalStorage DR550 SMB Version 1.0 ------ 27 May 2005 Page 5 Introduction IBM® TotalStorage® DR550 SMB, one of IBM’s Data Retention offerings, is an integrated offering for clients that need to retain and preserve electronic business records. The DR550 SMB packages storage, server and software retention components into a preconfigured offering.
IBM TotalStorage DR550 SMB Version 1.0 ------ 27 May 2005 Page 6 Hardware Overview The DR550 SMB includes one IBM eServer P5 520 server running AIX® 5.2, a flat panel monitor and keyboard, and when configured for tape attachment, a Fibre Channel SAN Switch is included in the offering. No clustering option is available.
IBM TotalStorage DR550 SMB Version 1.0 ------ 27 May 2005 • 2 10/100/1000 Ethernet ports (for copper based connections) – these are used to for connection to the external customer network • 2 serial ports (RS232).
IBM TotalStorage DR550 SMB Accessing the Switch(es) Version 1.0 ------ 27 May 2005 Page 8 If you need to access the switch(es) to review the zoning information, error messages, or other information, you will need to connect Ethernet cables (provided by the customer) to the Ethernet port on the switch. These cables would also need to be connected to the customer network. You can then access the switch using the IP address. The Userid is ADMIN and the password is PASSWORD.
IBM TotalStorage DR550 SMB Version 1.0 ------ 27 May 2005 Page 9 Software Overview Tivoli Storage Manager for Data Retention IBM Tivoli Storage Manager for Data Retention provides enhancements to IBM Tivoli Storage Manager Extended Edition (hereafter referred to as Tivoli Storage Manager) designed to prevent critical data from being erased or rewritten. This new product can help address requirements defined by many regulatory agencies for retention and disposition of data.
IBM TotalStorage DR550 SMB Version 1.0 ------ 27 May 2005 Page 10 IBM DB2 Content Manager To assist customers in addressing needs for data retention, IBM delivers DB2 Content Manager along with business consulting services (as needed). IBM® DB2® Content Manager provides a foundation for managing, accessing and integrating critical business information on demand.
IBM TotalStorage DR550 SMB Version 1.0 ------ 27 May 2005 Page 11 DR550 SMB DR550 SMB is available as a single node offering. The offering can also be customized to include support for tape, and the appropriate Ethernet connections.
IBM TotalStorage DR550 SMB Version 1.0 ------ 27 May 2005 5608-ISX IBM Tivoli Storage Manager Extended Edition 0165 5608-ISX (Processors) – Q 1 5809 5608-ISX CD-ROM ENU Page 12 1 1 1 5608-SX3 3345 IBM Tivoli Storage Manager Extended Edition Reg/Ren: 1Yr 5608-SX3 SW Maint No Charge 1Y Reg (Processors) 1 1 5608-TDR 0177 5809 IBM Tivoli Stg Mgr for Data Retention 5608-TDR Qty 1 English CD-ROM 1 1 1 5692-A5L 0947 0949 0965 0975 0976 1004 1432 2924 3410 5005 5924 System Software MEDIA 5765-E62 AIX V5.
IBM TotalStorage DR550 SMB Version 1.0 ------ 27 May 2005 Page 13 Logical Volume Configurations On the DR550 SMB, LUNs have been configured based on the total storage capacity ordered. All disk capacity is allocated for use by TSM. No disk capacity is set aside for other applications or servers. Below are the LUN configurations set at the factory. If you view the LUN id from AIX, it will be displayed as a hexadecimal address.
IBM TotalStorage DR550 SMB Version 1.0 ------ 27 May 2005 Page 14 Tivoli Storage Manager Server Configuration The Tivoli Storage Manager Server settings on the DR550 SMB should not be changed (these settings are different than the default settings). Other parameters use the default settings.
IBM TotalStorage DR550 SMB Version 1.0 ------ 27 May 2005 Page 15 Note: It is the responsibility of the customer to set up and verify schedules and database backups. You should verify that you have appropriate schedules in place to back up your database. Routine Operations for Tivoli Storage Manager Monitoring the Database and Recovery Log Status Monitor the Tivoli Storage Manager database and recovery usage log to ensure that you have enough space available for efficient operation.
IBM TotalStorage DR550 SMB Version 1.0 ------ 27 May 2005 Page 16 Installation and Activation Safety Notices A danger notice indicates the presence of a hazard that has the potential of causing death or serious injury. A caution notice indicates the presence of a hazard that has the potential of causing moderate or minor personal injury. Note: For a translation of these notices, see System Unit Safety Information, order number SA232652.
IBM TotalStorage DR550 SMB Version 1.0 ------ 27 May 2005 Page 17 Site Preparation and Planning Before you install the IBM TotalStorage DR550 SMB, we recommend that you consider several things to avoid problems during the installation and configuration. The DR550 SMB comes with preloaded and preconfigured software. No changes should be made to the software during the installation. The DR550 SMB will ship as separate components.
IBM TotalStorage DR550 SMB Version 1.
IBM TotalStorage DR550 SMB Version 1.0 ------ 27 May 2005 Page 19 Setting up the Management Console DR550 SMB includes an integrated management console. Connections are made through the Netbay LCM (Local Console Manager). To interact with the system software interfaces or to run diagnostics from a DVD-RAM, it is necessary to use the integrated console.
IBM TotalStorage DR550 SMB Version 1.
IBM TotalStorage DR550 SMB Version 1.0 ------ 27 May 2005 Page 21 5. Use a 9-pin to 9-pin serial converter cable (customer supplied) when connecting to the rear serial port 1. An ASCII (tty) terminal must be used to configure both P5 520 servers. If you have a single terminal, you may connect it to one P5 520 and configure the server. Then connect it to the other P5 520 server and configure it. Thus only one terminal is needed as the console in setting up the DR550 SMB.
IBM TotalStorage DR550 SMB Version 1.0 ------ 27 May 2005 Page 22 8. Verify that the grounding impedance is correct by using the ECOS 1020, 1023, B7106, C7106, or an appropriately approved ground-impedance tester. Cabling AC Many racks have sets of AC power rails (left and right) traversing vertically in the rear of the rack cabinet. Each rail in a set should be connected to a different AC power feed if that is available. This is to enhance the availability of the rack components.
IBM TotalStorage DR550 SMB Version 1.0 ------ 27 May 2005 Page 23 Configuring the P5 520 Server The P5 520 server within the IBM TotalStorage DR550 SMB is shipped with particular AIX security settings. These settings will not allow remote administration tasks initiated via commands like telnet, remote shell (rsh), file transfer protocol (ftp) or similar. Therefore, you should use the integrated console for management activities.
IBM TotalStorage DR550 SMB Account admin Version 1.0 ------ 27 May 2005 Roles Tivoli Storage Manager Administrator ID Admin login and password is for all TSM administrative usage http;//:1580 Page 24 Password set at Factory admin It is the customer’s responsibility to change the default passwords provided above and to record and protect the new passwords. Changing the password should be done during the initial installation.
IBM TotalStorage DR550 SMB Version 1.0 ------ 27 May 2005 Page 25 The following table shows the IP addresses associated with the server, storage and customer network. Please note that some addresses may need to be changed while others should not be changed. IP Address DRS_Engine_1 192.168.1.
IBM TotalStorage DR550 SMB Version 1.0 ------ 27 May 2005 Page 26 Procedure for Changing IP Address To configure the DR550 SMB for the use within your network you must change one IP address from its factory setting. The change is made to the P5 520 server.
IBM TotalStorage DR550 SMB Version 1.0 ------ 27 May 2005 Page 27 1. First of all create a copy of the /etc/hosts file that is shipped from factory (see Preconfigured /etc/hosts file on drs_engine (excerpt)) with the AIX command cp /etc/hosts /etc/hosts.factory. Preconfigured /etc/hosts file on drs_engine (excerpt) 127.0.0.1 192.168.1.21 loopback localhost # loopback (lo0) name/address drs_engine 2.
IBM TotalStorage DR550 SMB Version 1.0 ------ 27 May 2005 Page 28 You need to adjust the IBM Tivoli Storage Manager (ITSM) client system options file, so that the ITSM API or any ITSM client (dsmadmc) can find the IBM Tivoli Storage Manager server. On the p5 520 server, replace the value in the dsm.sys file for the tcpserveraddress with your new HACMP cluster service address. We recommend that you do NOT use a dot address, for instance 100.100.51.
IBM TotalStorage DR550 SMB Version 1.0 ------ 27 May 2005 Page 29 o Switch to the ibmce user ID and his environment with the AIX command su - ibmce. o Change the password of ibmce with the AIX command passwd. Follow the instructions on the screen. o Exit the shell back to the root environment with the AIX command exit. o Exit the shell back to the dr550 environment with the AIX command exit. o Exit the shell back to the AIX login screen with the AIX command exit.
IBM TotalStorage DR550 SMB Version 1.0 ------ 27 May 2005 Page 30 Enter the name of the DVD-RAM device. Pressing F4 will provide a list of device names (select /dev/cd0) Select yes or no for the mksysb creation options.
IBM TotalStorage DR550 SMB Version 1.0 ------ 27 May 2005 Page 31 Enter the location of installation images that are to be copied to the DVD file system (if any) in the Location of packages to copy to DVD field. This field is required if additional packages are to be placed on the DVD (see the previous step). The location can be a directory or DVD device. You can specify the full path name to a customization script in the Customization script field.
IBM TotalStorage DR550 SMB Version 1.0 ------ 27 May 2005 Page 32 1 Start Install Now with Default Settings >>> 2 Change/Show Installation Settings and Install 3 Start Maintenance Mode for System Recovery 88 Help ? 99 Previous Menu >>> Choice [1]: 2 Set and Verify Installation Settings 1.
IBM TotalStorage DR550 SMB 3 hdisk2 Version 1.0 ------ 27 May 2005 04-B0-00-6,0 12288 Page 33 none Yes >>> 0 Continue with choices indicated above 66 Disks not known to Base Operating System Installation 77 Display More Disk Information 88 Help ? 99 Previous Menu >>> Choice [0]: 4. Select the disk or disks you want to install by typing the number that corresponds to the hard disk name and pressing Enter. The disk will now be selected as indicated by >>>.
IBM TotalStorage DR550 SMB Version 1.0 ------ 27 May 2005 Page 34 Backing Up the DR550 SMB Data Chapter 22 in the TSM Administration Guide (titled Protecting the Server) has the details on how to protect the TSM database, server and storage pools. Backup jobs have already been setup for the data base and logs. You should review these jobs and modify if needed. Backing up the data needs to be setup, per the instructions in this chapter. There are several options that can be used to backup the data.
IBM TotalStorage DR550 SMB Version 1.0 ------ 27 May 2005 Page 35 Other Information Environmental Specifications The DR550 SMB consists of the following components. Each configuration is installed within a 7014 rack (one or two depending on configuration). Floor space requirements are based on the 7014-T00 rack (.85 square yards or .7 square meters). The following table lists estimates for each of the single node configurations. Configuration 1 TB – disk only 1 TB – disk and tape ready Weight (kg) 55.
IBM TotalStorage DR550 SMB Version 1.0 ------ 27 May 2005 7316-TF3 Physical Specifications Width: 485 mm (19 in) Depth: 635 mm to 730 mm (29.0 in to 28.74 in) Height (closed): 43.0 mm (1.7 in) Height (opened): 410 mm (16.1 in) Weight: 12.8 kg (28.2 lbs) LCD Panel Size: 432 mm (17 in) diagonal, 337.92 (H) x 270.34 mm (V) (13.3 in x 10.6 in) Type: a-Si TFT active matrix Pixel pitch: 0.264 mm (H) x 0.
IBM TotalStorage DR550 SMB Version 1.0 ------ 27 May 2005 Page 37 eraseability along with high performance. Whether you use the 3592 for backup of the DR550 SMB (using TSM commands such as “copy storage pool”) or you choose to archive directly to tape, the data is permanently stored and can not be modified. Using a different tape cartridge (without WORM protection) will not guarantee the non-erase capability that is featured in the DR550 SMB.
IBM TotalStorage DR550 SMB FC 4674 FC 4812 FC 6025 FC 9200 FC 9590 FC 9600 Version 1.0 ------ 27 May 2005 Install J1A in Rack Right Drive Cradle in Rack 25 Meter LC/LC Fibre Channel Cable Open System Device Drivers No Data Cartridge pSeries AIX Attachment Page 38 1 1 2 1 1 1 The 3592s can be placed inside of the 3584 or 3494 tape libraries or you can mount them in a separate rack. Please discuss the required library features with your local IBM sales team or business partner.
IBM TotalStorage DR550 SMB Version 1.0 ------ 27 May 2005 Page 39 Specifies that the server stops migration when no eligible files remain to be migrated, even before reaching the low migration threshold. The server does not migrate files unless the files satisfy the migration delay time.
IBM TotalStorage DR550 SMB Version 1.0 ------ 27 May 2005 Page 40 Problem Determination This section provides guidance for an entry point to perform problem determination on a DR550 SMB. Each underlying product that makes up a DR550 SMB provides problem determination information. A DR550 SMB is made up of these products: • One POWER5 520 • One IBM Flat Panel Monitor • One TotalStorage SAN Switches (2005-H08) – if configured for tape • AIX V5.2 ML6 • Tivoli Storage Manager Extended Edition V5.3.
IBM TotalStorage DR550 SMB Questions 1. Problem Definition Version 1.0 ------ 27 May 2005 Page 41 Responses 2. Time/Date of Failure 3. How was the problem detected? Does the problem existing on multiple machines? Was the error detected by a user? Was the error detected by the system? 4. 5. 6. 7. 8.
IBM TotalStorage DR550 SMB Problem Area External network communication P5 520 service request number or other server problem indications. P5 520 DR550 SAN; 2005-H08 Switch problems AIX Tivoli Storage Manager Version 1.0 ------ 27 May 2005 Page 42 Start with this information Check that the external network Ethernet cables are correctly connected to the servers.
IBM TotalStorage DR550 SMB Version 1.0 ------ 27 May 2005 Page 43 Additional sources of information The next table provides a list of books that contain problem determination information for each product that makes up a DR550 SMB. Unless indicated the information shipped with the DR550 SMB either as a printed book or on a documentation CD.
IBM TotalStorage DR550 SMB Version 1.0 ------ 27 May 2005 Page 44 Viewing the AIX runtime error log Log on to the system as the ibmce user. Check the system error log by entering the following command at the AIX prompt: Cat /var/log/messages |grep RTAS |more The run-time error messages are logged in the messages file under /var/log. Support Web Site http://www-1.ibm.com/servers/storage/support/disk/dr.html has additional information applicable to the DR550 SMB.
IBM TotalStorage DR550 SMB Version 1.0 ------ 27 May 2005 Page 45 Legal Notices Copyright © 2005 by International Business Machines Corporation, All rights reserved. No part of this document may be reproduced or transmitted in any form without written permission from IBM. Product data has been reviewed for accuracy as of the date of initial publication. Product data is subject to change without notice. This information could include technical inaccuracies or typographical errors.
IBM TotalStorage DR550 SMB Version 1.0 ------ 27 May 2005 provide legal advice or represent or warrant that its services or products will ensure that the customer is in compliance with any law.
IBM TotalStorage DR550 SMB Version 1.0 ------ 27 May 2005 9. IBM Tivoli Storage Management Concepts, SG24-4877-03 Page 47 10. IBM SAN Survival Guide Featuring the McDATA Portfolio, SG24-6149-01 11. Fast path configuration using the Guided Setup wizard http://publib.boulder.ibm.com/infocenter/eserver/v1r2s/en_US/index.htm 12. Serial port setup http://publib.boulder.ibm.com/infocenter/eserver/v1r2s/en_US/index.htm 13. Setting up the service processor to connect to your service provider http://publib.
IBM TotalStorage DR550 SMB Version 1.0 ------ 27 May 2005 Page 48 Updates To This Guide Updates to this guide will be made as warranted and can be downloaded from the web at: HTTP://WWW.STORAGE.IBM.COM/DISK/DR/INDEX.