User manual
CTI 2572 Installation and Operation Guide
112
HEX DEC DESCRIPTION SOLUTION
24A1 9377 DATA BITS SELECTION ERROR
(Serial Ports Only). The protocol manager was
passed an invalid value for data bits. Valid
data bit values are 5, 6, 7, 8.
See error code 24A0
24A2 9388 PARITY SELECTION ERROR
(Serial Ports Only). The protocol manager was
passed an invalid parity value. Valid parity
values are 0-None, 1-Odd, 2-Even.
See error code 24A0
24A3 9379 STOP BIT SELECTION ERROR
(Serial Ports Only). The protocol manager was
passed an invalid number of stop bits. Valid
stop bit values are 1 and 2.
See error code 24A0
24A4 9380 HANDSHAKE SELECTION ERROR
(Serial Ports Only). The protocol manager was
passed an invalid handshake value. Valid
handshake values are:
0-No Handshake, 1-Software Handshake,
2-Hardware Handshake.
See error code 24A0
24AC 9388 MEMORY READ ERROR
The 2572 was unable to read the requested V
memory.
When this error occurs, it is usually due to an
invalid memory address specification in the
command block. Check the command block
and make corrections if necessary.
Check to ensure that the PLC you are
addressing is configured for the address you
are trying to access.