User's Manual
3745 Panel Codes
Table 1-5 (Page 14 of 33). Panel Codes. An
ñ
following a panel code denotes that the code should 'Blink'.
Panel
Code
Definition
Action: Go to “3745 FRU Group
Table” on page 1-49
or to MAP number
A38ñ
Moss level 0 error detection; MCCU A; PIO; Timeout;
Outbound address parity check
Exchange the FRU group 20
A39ñ
Moss level 0 error detection; MCCU A; PIO; Timeout;
Adapter not detected
A3Añ
Moss level 0 error detection; MCCU A; PIO; Timeout;
Adapter failure
A3Bñ
Moss level 0 error detection; MCCU A; PIO; Timeout;
Multiple bits detected in Stat reg
A3C to A67 Unused
Go to “MAP 3220: Undefined Panel
Message” on page 2-5
A68ñ Moss level 0 error detection; SWAD; Adapter is 'down'
Exchange the FRU group 5
A69ñ
Moss level 0 error detection; SWAD; Adapter is 'down';
Excess spurious errors
A6Añ
Moss level 0 error detection; SWAD; Adapter check;
Internal clock check 1
A6Bñ
Moss level 0 error detection; SWAD; Adapter check;
Internal clock check 2
A6Cñ
Moss level 0 error detection; SWAD; Adapter check;
Multiple bits detected in Disconnect reg
Exchange the FRU group 5
A6Dñ
Moss level 0 error detection; SWAD; Device; Adapter
check; State counter parity
A6Eñ
Moss level 0 error detection; SWAD; Device; Adapter
check; Shift pulse counter parity
A6Fñ
Moss level 0 error detection; SWAD; Device; Adapter
check; Ground fault detected on a driver line
A70ñ
Moss level 0 error detection; SWAD; Device; Adapter
check; Interface check
Exchange the FRU group 5
A71ñ
Moss level 0 error detection; SWAD; Device; Adapter
check; Interface timeout
A72ñ
Moss level 0 error detection; SWAD; Device; Adapter
check; Interface parity check
A73ñ
Moss level 0 error detection; SWAD; Device; Adapter
check; Multiple bits detected in EB Stat reg
A74ñ
Moss level 0 error detection; SWAD; Device; Adapter
check; Switch interface error
Exchange the FRU group 5
A75ñ
Moss level 0 error detection; SWAD; Device; Adapter
check; Switch driver fault
A76ñ
Moss level 0 error detection; SWAD; Device; Adapter
check; Switch serial link parity
A77ñ
Moss level 0 error detection; SWAD; Device; Adapter
check; Switch invalid command
A78ñ
Moss level 0 error detection; SWAD; Device; Adapter
check; Multiple bits detected in Device stat reg
Exchange the FRU group 5
A79ñ
Moss level 0 error detection; SWAD; Device; Adapter
check; Adapter failure
A7Añ
Moss level 0 error detection; SWAD; Device; Adapter
check; No Common Adapter Code running
A7Bñ
Moss level 0 error detection; SWAD; PIO; Bus check;
Inbound parity
A7Cñ
Moss level 0 error detection; SWAD; PIO; Bus check;
Adapter failure
Exchange the FRU group 5
A7Dñ
Moss level 0 error detection; SWAD; PIO; Bus check;
Adapter not detected
A7Eñ
Moss level 0 error detection; SWAD; PIO; Timeout;
Invalid command
A7Fñ
Moss level 0 error detection; SWAD; PIO; Timeout;
Outbound address parity check
1-28 3745 Models 130 to 17A: MIP