User's Manual

3745 Panel Codes
Table 1-5 (Page 12 of 33). Panel Codes. An
ñ
following a panel code denotes that the code should 'Blink'.
Panel
Code
Definition
Action: Go to “3745 FRU Group
Table” on page 1-49
or to MAP number
200 to 9FF Unused
Go to “MAP 3220: Undefined Panel
Message” on page 2-5
A00ñ
Moss level 0 error detection; MCCU A or SWAD
Adapter is 'down'; Excess spurious errors
Exchange the FRU group 5
A01ñ Moss level 0 error detection; PCA1; Adapter is 'down'
A02ñ
Moss level 0 error detection; PCA1; PIO Bus Check;
Inbound parity
A03ñ
Moss level 0 error detection; PCA1; PIO Bus Check;
Adapter not detected
A04ñ
Moss level 0 error detection; PCA1; PIO Timeout; Out-
bound; Address parity check
Exchange the FRU group 5
A05ñ
Moss level 0 error detection; PCA1; PIO Timeout; Out-
bound; Command/data parity check
A06ñ Moss level 0 error detection; PCA2; Adapter is 'down'
A07ñ
Moss level 0 error detection; PCA2; PIO Bus Check;
Inbound parity
A08ñ
Moss level 0 error detection; PCA2; PIO Bus Check;
Adapter not detected
Exchange the FRU group 5
A09ñ
Moss level 0 error detection; PCA2; PIO Timeout; Out-
bound; Address parity check
A0Añ
Moss level 0 error detection; PCA2; PIO Timeout; Out-
bound; Command/data parity check
A0Bñ Moss level 0 error detection; PCA3; Adapter is 'down'
A0Cñ
Moss level 0 error detection; PCA3; PIO Bus Check;
Inbound parity
Exchange the FRU group 5
A0Dñ
Moss level 0 error detection; PCA3; PIO Bus Check;
Adapter not detected
A0Eñ
Moss level 0 error detection; PCA3; PIO Timeout; Out-
bound; Address parity check
A0Fñ
Moss level 0 error detection; PCA3; PIO Timeout; Out-
bound; Command/data parity check
A10ñ
Moss level 0 error detection; MCCU A; Adapter is
'down'
Exchange the FRU group 5A11ñ
Moss level 0 error detection; MCCU A; Adapter is
'down'; Excess
spurious errors
A12ñ
Moss level 0 error detection; MCCU A; Adapter check;
1 usec counter parity
A13ñ
Moss level 0 error detection; MCCU A; Adapter check;
MIOC/CCU timeout parity
Exchange the FRU group 20
A14ñ
Moss level 0 error detection; MCCU A; CHIO Bus
check
A15ñ Moss level 0 error detection; MCCU A; CHIO Timeout
A16ñ
Moss level 0 error detection; MCCU A; CHIO; Storage
ECC error;
Register space parity during main store.
Exchange the FRU group 42
A17ñ
Moss level 0 error detection; MCCU A; CHIO; Storage
ECC error;
Multiple bits in DIV Register
A18ñ
Moss level 0 error detection; MCCU A; CHIO; Storage
ECC error; No bits active in DIV Register
Exchange the FRU group 5. Record
the following action for use if the
problem is not corrected by the FRU
exchange; A MOSS microcode
problem is suspected. Call your
support structure, refer to “Contacting
Support” on page A-1.
A19ñ
Moss level 0 error detection; MCCU A; CHIO; Excep-
tion; Address
exception on main store data access
A1Añ
Moss level 0 error detection; MCCU A; CHIO; Excep-
tion; Operation exception; CHCV Register invalid
A1Bñ
Moss level 0 error detection; MCCU A; CHIO; Excep-
tion; Register
precision; CHP Register bits 0-7 are not zero
1-26 3745 Models 130 to 17A: MIP