User's Manual
3745 Panel Codes
Table 1-5 (Page 5 of 33). Panel Codes. An
ñ
following a panel code denotes that the code should 'Blink'.
Panel
Code
Definition
Action: Go to “3745 FRU Group
Table” on page 1-49
or to MAP number
0DFñ
IOIRV REGISTER IS X'00' IN TEST 2 NO INTER-
RUPT REQUESTED
Exchange the FRU group 15
0E0ñ CHIO TRANSFER KO
0E1ñ
ADAPTER IN BUSY STATE IN TEST 4 BSTAT BITS
0,1 ARE NOT B'00' OR ADAPTER NOT ENABLE
BSTAT BIT 6 IS NOT ONE RUN DIAGNOSTIC
COMMAND TEST
0E2ñ
DATA TRANSMISSION ERROR HSTAT BITS
0,1,2,3,6,7 ARE NOT ZERO RUN DIAGNOSTIC
COMMAND TEST
0E3ñ
DIFFERENT CONTENTS IN THE FIRST AND THE
SECOND PART OF THE SECTOR BUFFER RUN
DIAGNOSTIC COMMAND TEST
Exchange the FRU group 15
0E4ñ
ERROR IN SSB BYTE 0 RUN DIAGNOSTIC
COMMAND TEST
Exchange the FRU group 21
0E5ñ
ERROR IN SSB BYTE 1 AND 2 RUN DIAGNOSTIC
COMMAND TEST
Exchange the FRU group 15
0E6ñ
ADAPTER IN BUSY STATE IN TEST 5 BSTAT BITS
0,1 ARE NOT B'00' OR ADAPTER NOT ENABLE
BSTAT BIT 6 IS NOT ONE DRIVES INITIALIZATION
Exchange the FRU group 16
0E7ñ
IOIRV REGISTER IS X'00' IN TEST 5 NO INTER-
RUPT RECEIVED DRIVES INITIALIZATION
0E8ñ
EIRV REGISTER IS NOT X'00' IN TEST 5 DRIVES
INITIALIZATION
0E9ñ
DATA TRANSMISSION ERROR HSTAT BITS
0,1,2,3,6,7 ARE NOT ZERO DRIVES INITIALIZATION
0EAñ
ADAPTER IN BUSY STATE IN TEST 6 BSTAT BITS
0,1 ARE NOT B'00' OR ADAPTER NOT ENABLE
BSTAT BIT 6 IS NOT ONE SEEK COMMAND
BEFORE RECALIBRATE TEST
Exchange the FRU group 16
0EBñ
IOIRV REGISTER IS X'00' IN TEST 6 NO INTER-
RUPT RECEIVED SEEK COMMAND BEFORE
RECALIBRATE TEST
0EDñ
ADAPTER IN BUSY STATE IN TEST 6 BSTAT BITS
0,1 ARE NOT B'00' OR ADAPTER NOT ENABLE
BSTAT BIT 6 IS NOT ONE RECALIBRATE COMMAND
TEST
0EEñ
IOIRV REGISTER IS X'00' IN TEST 6 NO INTER-
RUPT RECEIVED RECALIBRATE COMMAND TEST
0EFñ
EIRV REGISTER IS NOT X'00' IN TEST 6 RECALI-
BRATE COMMAND TEST
Exchange the FRU group 16
0F0 Unused
Go to “MAP 3220: Undefined Panel
Message” on page 2-5
0F1ñ
DATA TRANSMISSION ERROR HSTAT BITS
0,1,2,3,6,7 ARE NOT ZERO DRIVES INITIALIZATION
RECALIBRATE COMMAND TEST
Exchange the FRU group 16
0F2ñ
NO CYLINDER ZERO IN SSB BYTE0 BIT 7 RECALI-
BRATE COMMAND TEST
0F3ñ
ERROR IN SSB BYTE 0 RECALIBRATE COMMAND
TEST
Exchange the FRU group 16
0F4ñ
ERROR IN SSB BYTE 1 AND 2 RECALIBRATE
COMMAND TEST
0F5ñ
ADAPTER IN BUSY STATE IN TEST 7 BSTAT BITS
0,1 ARE NOT B'00' OR ADAPTER NOT ENABLE
BSTAT BIT 6 IS NOT ONE READ ID COMMAND TEST
0F6ñ
IOIRV REGISTER IS X'00' IN TEST 7 NO INTER-
RUPT RECEIVED READ ID COMMAND TEST
Chapter 1. START: How to Begin Troubleshooting 1-19