User's Manual
3745 Panel Codes
Table 1-5 (Page 4 of 33). Panel Codes. An
ñ
following a panel code denotes that the code should 'Blink'.
Panel
Code
Definition
Action: Go to “3745 FRU Group
Table” on page 1-49
or to MAP number
0ADñ NO SINGLE ERROR CORRECTION IN TEST 3
Exchange the FRU group 13
0AEñ BAD SINGLE ERROR CORRECTION IN TEST 3
0AF Unused
Go to “MAP 3220: Undefined Panel
Message” on page 2-5
0B0ñ NO DOUBLE ERROR DETECTION IN TEST 3 Exchange the FRU group 13
0B1ñ
DIFFERENT LOADED AND STORED CONTENTS IN
TEST 4
Exchange the FRU group 11
0B2ñ
RECONFIGURE BIT IN TOD ADAPTER CAN NOT BE
SET IN TEST 5
Exchange the FRU group 13
0B3 Unused
Go to “MAP 3220: Undefined Panel
Message” on page 2-5
0B4ñ
DIFFERENT LOADED AND STORED CONTENTS IN
TEST 7
Exchange the FRU group 11
0B5ñ DOUBLE UNCORRECTABLE ERROR IN TEST 6 Exchange the FRU group 13
0B6ñ ENABLE VALID OPTION KO IN TEST 9 Exchange the FRU group 12
0B7ñ EIRV REGISTER IS NOT X'00' IN TEST 9 Exchange the FRU group 13
0B8 to 0BE Unused
Go to “MAP 3220: Undefined Panel
Message” on page 2-5
0BF MOSS MEMORY TEST EXIT CODE Progression code.
If permanently displayed, exchange
the FRU group 2
0C0
PROBLEM IN ROS MAINLINE CONTROLLER INITIAL-
IZATION
Exchange the FRU group 14
0C1
CONTROL LOST AFTER INITIALIZING THE ROS
MAINLINE CONTROLLER
Exchange the FRU group 2
0C2 CONTROL LOST DURING PSV SWAP TEST Exchange the FRU group 13
0C3ñ
STORAGE CHECK (WHEN ACCESSING THE REG-
ISTER SPACE)
Exchange the FRU group 11
0C4ñ
SCHEDULED PROGRESSION NOT PERFORMED
DURING THE PSV SWAP TEST
Exchange FRU group 13
0C5ñ
CACHE IN/CACHE OUT OPERATION NOT SUC-
CESSFUL
0C6 Unused
Go to “MAP 3220: Undefined Panel
Message” on page 2-5
0C7 PSV SWAP TEST SUCCESSFUL Progression code.
If permanently displayed, exchange
the FRU group 2
0C8 to 0CF Unused
Go to “MAP 3220: Undefined Panel
Message” on page 2-5
0D0ñ
DISK ADAPTER TEST ENTRY CODE Progression
code.
If permanently displayed, exchange
the FRU group 2
0D1ñ EIRV REGISTER IS NOT X'00' IN TEST 1 Exchange the FRU group 54
0D2ñ IOIRV REGISTER IS NOT X'00' IN TEST 1
Exchange the FRU group 15
0D3ñ
ADAPTER NOT IN BUSY STATE OR NOT ENABLE
BSTAT BITS 0,1 ARE NOT B'10' IN TEST 1
0D4 Unused
Go to “MAP 3220: Undefined Panel
Message” on page 2-5
0D5ñ
ADAPTER NOT IN IDLE STATE IN TEST 1 BSTAT
BITS 0,1 ARE NOT B'00'
Exchange the FRU group 15
0D6ñ
DIFFERENT LOADED AND READ CONTENTS IN
TEST 2
0D7ñ
REGISTER NOT RESET AFTER A RESET COMMAND
IN TEST 2
Exchange the FRU group 15
0D8ñ INVALID PIO COMMAND
0D9ñ EIRV REGISTER IS NOT X'00' IN TEST 2
0DAñ IOIRV REGISTER IS NOT X'00' IN TEST 2
0DBñ
ADAPTER IN BUSY STATE IN TEST 1 BSTAT BITS
0,1 ARE NOT B'00'
Exchange the FRU group 15
0DCñ EIRV REGISTER IS NOT X'00' IN TEST 3
0DDñ IOIRV REGISTER IS NOT X'00' IN TEST 2
0DEñ EIRV REGISTER IS NOT X'00' IN TEST 3
1-18 3745 Models 130 to 17A: MIP