User's Manual
3745 Panel Codes
Table 1-5 (Page 23 of 33). Panel Codes. An
ñ
following a panel code denotes that the code should 'Blink'.
Panel
Code
Definition
Action: Go to “3745 FRU Group
Table” on page 1-49
or to MAP number
C35ñ
Moss level 0 error detection; MOSS ABEND; Operator
Control; Data stream out is greater than 1024 bytes
A MOSS microcode problem is sus-
pected. Contact your support struc-
ture, refer to “Contacting Support” on
page A-1.
C36ñ
Moss level 0 error detection; MOSS ABEND; CCU
Functions; End of DCF application
C37ñ
Moss level 0 error detection; MOSS ABEND; CCU
Functions; Incorrect load module identified
C38ñ
Moss level 0 error detection; MOSS ABEND; CCU
Functions; Logical disk error
C39ñ
Moss level 0 error detection; MOSS ABEND; CCU
Functions; Unknown operator control return code
A MOSS microcode problem is sus-
pected. Contact your support struc-
ture, refer to “Contacting Support” on
page A-1.
C3Añ
Moss level 0 error detection; MOSS ABEND; Transient
Tasks; Load module not found
C3Bñ
Moss level 0 error detection; MOSS ABEND; Transient
Tasks; Logical disk error
C3Cñ
Moss level 0 error detection; MOSS ABEND; Transient
Tasks; Unknown operator control return code
C3Dñ
Moss level 0 error detection; MOSS ABEND; Transient
Tasks; Conflicting dump file information
A MOSS microcode problem is sus-
pected. Contact your support struc-
ture, refer to “Contacting Support” on
page A-1.
C3Eñ
Moss level 0 error detection; MOSS ABEND; Transient
Tasks; Scanner not installed or SCB not flagged "auto
dump"
C3Fñ
Moss level 0 error detection; MOSS ABEND; Transient
Tasks; Control program invalid answer
C40ñ
Moss level 0 error detection; MOSS ABEND; Transient
Tasks; Disconnect not allowed
C41ñ
Moss level 0 error detection; MOSS ABEND; Transient
Tasks; Buffer limit reached
A MOSS microcode problem is sus-
pected. Contact your support struc-
ture, refer to “Contacting Support” on
page A-1.
C42ñ
Moss level 0 error detection; MOSS ABEND; Box Error
Logging; Invalid BER stack
C43ñ
Moss level 0 error detection; MOSS ABEND; Mail Box
Support; Load module not found
C44ñ
Moss level 0 error detection; MOSS ABEND; Mail Box
Support; Mail box request rejected
C45ñ
Moss level 0 error detection; MOSS ABEND; Mail Box
Support;
Unsolicited call
A MOSS microcode problem is sus-
pected. Contact your support struc-
ture, refer to “Contacting Support” on
page A-1.
C46ñ
Moss level 0 error detection; MOSS ABEND; Mail Box
Support; Invalid RU
C47ñ
Moss level 0 error detection; MOSS ABEND; Macro
Invocation; Started bit in request
C48ñ
Moss level 0 error detection; MOSS ABEND; System
IPL; Start IPL refused
C49ñ
Moss level 0 error detection; MOSS ABEND; Disk
Functions; Disk
unusable
A MOSS microcode problem is sus-
pected. Contact your support struc-
ture, refer to “Contacting Support” on
page A-1.
C4Añ
Moss level 0 error detection; MOSS ABEND; Disk
Functions; Unable to load CHGDFINT
C4Bñ
Moss level 0 error detection; MOSS ABEND; Power
Functions; Incorrect access to PCST
C4Cñ
Moss level 0 error detection; MOSS ABEND; Power
Functions; Invalid data - threshold
C4Dñ
Moss level 0 error detection; MOSS ABEND; Power
Functions; Next request received before RP
A MOSS microcode problem is sus-
pected. Contact your support struc-
ture, refer to “Contacting Support” on
page A-1.
C4Eñ
Moss level 0 error detection; MOSS ABEND; Level 1;
Permanent HLIR - kill MOSS
C4Fñ
Moss level 0 error detection; MOSS ABEND; Level 1;
Excess amount of spurious errors
C50ñ
Moss level 0 error detection; MOSS ABEND; Level 1;
Soft checker - snapshot
Chapter 1. START: How to Begin Troubleshooting 1-37