3745 Panel Codes
Table 1-5 (Page 17 of 33). Panel Codes. An
ñ
following a panel code denotes that the code should 'Blink'.
Panel
Code
Definition
Action: Go to “3745 FRU Group
Table” on page 1-49
or to MAP number
AB9ñ
Moss level 0 error detection; Loop; Excessive MOSS
IML loop is detected via a TOD interrupt
Exchange the FRU group 13 the FRU
exchange; A MOSS microcode
problem is suspected. Call your
support structure, refer to “Contacting
Support” on page A-1.
ABAñ
Moss level 0 error detection; Erroneous MOSS code;
Program error; IO address is not authorized Record the
following action for use if the problem is not corrected
by
ABBñ
Moss level 0 error detection; Diag code; Program error;
Power on reset / start; Unresolved
ABCñ
Moss level 0 error detection; Level 0 code; Program
error; Invalid BER set during Checkpoint Retry
Recovery
ABDñ
Moss level 0 error detection; Level 0 code; Program
error; Invalid BER set during Postponed Retry Recovery
Exchange the FRU group 13. Record
the following action for use if the
problem is not corrected by the FRU
exchange; A MOSS microcode
problem is suspected. Call your
support structure, refer to “Contacting
Support” on page A-1.
ABEñ
Moss level 0 error detection; Level 0 code; Program
error; Invalid BER set during Transparent Retry
Recovery your support structure, refer to “Contacting
Support” on page A-1.
ABFñ
Moss level 0 error detection; Level 0 code; Program
error; Program request dispatcher - module
CHGH0PGM - is in an unexpected state
AC0ñ
Moss level 0 error detection; Level 0 code; Program
error; Invalid adaptor ID present in module CHGH0BUS
AC1ñ
Moss level 0 error detection; Level 0 code; Program
error; Ram processor is in an unexpected state
Exchange the FRU group 13. Record
the following action for use if the
problem is not corrected by the FRU
exchange; A MOSS microcode
problem is suspected. Call your
support structure, refer to “Contacting
Support” on page A-1.
AC2ñ
Moss level 0 error detection; Level 0 code; Program
error; Ros processor is in an unexpected state your
support structure, refer to “Contacting Support” on
page A-1.
AC3ñ
Moss level 0 error detection; Level 0 code; Program
error; Call address stack table is full
AC4ñ
Moss level 0 error detection; Level 0 code; Program
error; Return address stack table is empty
AC5ñ
Moss level 0 error detection; Level 0 code; Program
error; The type of BER created does not exist in the
BER table
Exchange the FRU group 13. Record
the following action for use if the
problem is not corrected by the FRU
exchange; A MOSS microcode
problem is suspected. Call your
support structure, refer to “Contacting
Support” on page A-1.
AC6ñ
Moss level 0 error detection; Level 0 code; Program
error; Moss already IML'd routine before the IML routine
your support structure, refer to “Contacting Support” on
page A-1.
AC7ñ
Moss level 0 error detection; Unexpected spurious inter-
rupt; CHIO error detected
AC8ñ
Moss level 0 error detection; Unexpected spurious inter-
rupt; Level 0 interrupt detected
AC9ñ
Moss level 0 error detection; Unexpected spurious inter-
rupt; Level 0 interrupt in IOIRV detected
Exchange the FRU group 5. Record
the following action for use if the
problem is not corrected by the FRU
exchange; A MOSS microcode
problem is suspected. Call your
support structure, refer to “Contacting
Support” on page A-1.
ACAñ
Moss level 0 error detection; Unexpected spurious inter-
rupt; PIO Bus check; No adaptor found with Last Pri-
ority Level
Exchange the FRU group 9. Record
the following action for use if the
problem is not corrected by the FRU
exchange; A MOSS microcode
problem is suspected. Call your
support structure, refer to “Contacting
Support” on page A-1.
ACBñ
Moss level 0 error detection; Unexpected spurious inter-
rupt; PIO Bus check; Instruction was not an IO type
ACCñ
Moss level 0 error detection; Unexpected spurious inter-
rupt; PIO Bus check; Detected on level 2
ACDñ
Moss level 0 error detection; Unexpected spurious inter-
rupt; PIO Bus check; Detected on level 6
Chapter 1. START: How to Begin Troubleshooting 1-31