22
ASHRAE class A2
Temperature: 10° to 35°C (50° to 95°F) to 914 m (3,000 ft)
Relative humidity: 8% to 80% (noncondensing)
NEBS environment
Air temperature:
Chassis on: 5° to 40°C (41° to 104°F) at altitude of -60 m (-197 ft) to 1,800
m (6,000 ft)
Chassis on (short term*): -5° to 55°C (23° to 131°F) at altitude of -60 m
(-197 ft) to 1,800 m (6,000 ft)
Chassis on: 5° to 30°C (41° to 86°F) at altitude of 1,800 m (600 ft) to 4,000
m (13,000 ft)
Chassis on (short term*): -5° to 45°C (23° to 113°F) at altitude of 1,800 m
(6,000 ft) to 4,000 m (13,000 ft)
Chassis off: -40° to 70°C (-40° to 158°F)
Rate of temperature change: 30°C/hr (54°F/hr)
Humidity:
Chassis on: 5% to 85%
Chassis on (short term*): 5% to 90% but not to exceed 0.024 kg water/kg of
dry air
Chassis off: uncontrolled
(*) Note: A period of not more than 96 consecutive hours and a total of not more
than 15 days in one year. (This refers to a total of 360 hours in any given year, but,
no more than 15 occurrences during that one-year period.)
Hardware requirements
For attended installation of an operating system, this server requires a compatible:
Keyboard
Mouse
Display
Unattended or remote installation may be performed without requiring some or
all of these components. Review your unattended software installation program
information for specific hardware configuration requirements.
For service, the server requires a compatible:
Keyboard
Mouse
Display
When having the unit serviced, plan to have these components attached to your
server either directly or indirectly via a console switch.
Software requirements
The following network operating systems have been tested for compatibility with the
BladeCenter HS23:
Microsoft :
Windows Server 2008 R2
Windows Server 2008 (32-bit) - Web/Std/Ent/DC
Windows Server 2008 (64-bit) - Web/Std/Ent/DC
Windows HPC Server 2008