User's Manual
Table Of Contents
- Contents
- Chapter 1. General Checkout
- Chapter 2. General Information
- Chapter 3. Diagnostics
- Setup Utility program
- Product Recovery Program menu
- Diagnostics
- Diagnostics download
- Navigating through the diagnostic programs
- Running diagnostic tests
- Test selection
- Module test menu/hardware configuration report
- Memory Diagnostic tests
- Alert-On LAN™ test
- Asset ID™ test
- Test results
- Hard file Smart test
- Fixed Disk Optimized Test
- Quick and Full erase - hard drive
- Iomega Zip drive test
- Asset EEPROM backup
- Viewing the test log
- When to use the Low-Level Format program
- Preparing the hard disk drive for use
- Chapter 4. Installing Options
- Chapter 5. FRU Replacements
- Chapter 6. Symptom-to-FRU Index
- Chapter 7. Parts
- Chapter 8. Additional Service Information
- Chapter 9. About this manual
- Chapter 10. Related Service Information

POST Error Code FRU/Action
1102
Card selected feedback error
1. Run diagnostics
1103
Port fails register check
1. Run diagnostics
2. System Board
1106
Serial option cannot be turned off
1. Run diagnostics
2. System Board
1107
1. Serial Device Cable
2. System Board
1110
Register test failed
1. Run diagnostics
2. System Board
1116
Interrupt error
1. Run diagnostics
1117
Failed baud rate test
1. Run diagnostics
1162
Serial port configuration error
1. Run Configuration
2. Serial Adapter
(if installed)
3. System Board
11XX
Not listed above
1. System Board
1201
1. System Board
2. Any Serial Device
1202, 1206, 1208, 1209, 12XX
1. Dual Async Adapter/A
2. System Board
3. Any Serial Device
1207
1. Communications Cable
2. Dual Async Adapter/A
13XX
1. Game Adapter
1402
Printer not ready
Information only
1403
No paper error, or interrupt failure
Information only
1404
System board timeout failure
1. Run diagnostics
1405
Parallel adapter error
1. Run diagnostics
1406
Presence test error
1. Run diagnostics
14XX
Not listed above. Check printer before
replacing system board
1. Printer
2. System Board
15XX
1. SDLC Adapter
1692
Boot sequence error
1. Run FDISK to ensure at least one active
partition is set active
64 Hardware Maintenance Manual A40 Type 6840 A40P Type 6841 A40i Type 2271: IBM NetVista Computer