Personal Computer User Manual
Table Of Contents
- Contents
- Chapter 1. General Checkout
- Chapter 2. General Information
- Chapter 3. Diagnostics
- Setup Utility program
- Product Recovery Program menu
- Diagnostics
- Diagnostics download
- Navigating through the diagnostic programs
- Running diagnostic tests
- Test selection
- Module test menu/hardware configuration report
- Memory Diagnostic tests
- Alert-On LAN™ test
- Asset ID™ test
- Test results
- Hard file Smart test
- Fixed Disk Optimized Test
- Quick and Full erase - hard drive
- Iomega Zip drive test
- Asset EEPROM backup
- Viewing the test log
- When to use the Low-Level Format program
- Preparing the hard disk drive for use
- Chapter 4. Installing Options
- Chapter 5. FRU Replacements
- Chapter 6. Symptom-to-FRU Index
- Chapter 7. Parts
- Chapter 8. Additional Service Information
- Chapter 9. About this manual
- Chapter 10. Related Service Information

Diagnostic Error Code FRU/Action
035-196-XXX
RAID interface test halt, error threshold
exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
035-197-XXX
RAID interface test warning
1. Make sure the component that is called
out is connected and/or enabled
2. Re-run test
3. Component that is called out in warning
statement
4. Component under test
035-198-XXX
RAID interface test aborted
1. If a component is called out, make sure
it is connected and/or enabled
2. Flash the system and re-test
3. Go to the ″Undetermined problems″
section
035-199-XXX
RAID interface test failed, cause unknown
1. Go to the ″Undetermined problems″
section
2. Flash the system and re-test
3. Replace component under function test
071-000-XXX
Audio port Interface Test Passed
1. No action
071-00X-XXX
071-01X-XXX
071-02X-XXX
Audio port error
1. Run Setup
2. Flash the system
3. System board
071-03X-XXX
Audio port failure
1. Speakers
2. Microphone
3. Audio card, if installed
4. System board
071-04X-XXX
Audio port failure
1. Run Setup
2. Audio card, if installed
3. System board
071-195-XXX
Audio port Test aborted by user
1. Information
2. Re-start the test, if necessary
071-196-XXX
Audio port test halt, error threshold
exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
071-197-XXX
Audio port test warning
1. Make sure the component that is called
out is connected and/or enabled
2. Re-run test
3. Component that is called out in warning
statement
4. Component under test
071-198-XXX
Audio port test aborted
1. If a component is called out, make sure
it is connected and/or enabled
2. Flash the system and re-test
3. Go to the ″Undetermined problems″
section
Chapter 6. Symptom-to-FRU Index 51