Datasheet
IBM Flex System x240 Compute Node 25
Figure 11. Location of x240 light path diagnostics panel
To illuminate the light path diagnostics LEDs, power off the compute node, slide it out of the chassis, and
press the power button. The power button doubles as the light path diagnostics remind button when the
server is removed from the chassis.
The meanings of the LEDs in the light path diagnostics panel are listed in the following table.
Table 19. Light path diagnostic panel LEDs
LED Meaning
LP The light path diagnostics panel is operational.
S BRD A system board error is detected.
MIS A mismatch has occurred between the processors, DIMMs, or HDDs within the configuration as
reported by POST.
NMI A non maskable interrupt (NMI) has occurred.
TEMP An over-temperature condition occurs that was critical enough to shut down the server.
MEM A memory fault has occurred. The corresponding DIMM error LEDs on the system board are also lit.
ADJ A fault is detected in the adjacent expansion unit (if installed).