User Manual

Intel
®
Xeon
®
Processor 5600 Series Datasheet Volume 1 123
Thermal Specifications
Notes:
1. The Thermal Profile is representative of a volumetrically constrained platform. Please refer to Table 7-10 for
discrete points that constitute the thermal profile.
2. Implementation of the Thermal Profile should result in virtually no TCC activation. Utilization of thermal
solutions that do not meet the Thermal Profile will result in increased probability of TCC activation and may
incur measurable performance loss.
3. Refer to the Intel® Xeon® Processor 5500/5600 Series Thermal/Mechanical Design Guidelines for system
and environmental implementation details.
Figure 7-5. Standard Server/Workstation Platform Thermal Profile (6 Core)
45
50
55
60
65
70
75
80
0 1020304050607080
Powe r [W]
Temperature [C]
Y = 0.306*x + 51.7
45
50
55
60
65
70
75
80
0 1020304050607080
Powe r [W]
Temperature [C]
Y = 0.306*x + 51.7
Table 7-10. Standard Server/Workstation Platform Thermal Profile (6 Core)
Power (W) T
CASE_MAX
(C)
051.7
10 54.8
20 57.8
30 60.9
40 63.9
50 67.0
60 70.1
70 73.1
80 76.2