Processor 5600 Series Datasheet Volume 1 117
Thermal Specifications
Notes:
1. The Frequency Optimized Server/Workstation Thermal Profile is representative of a volumetrically
unconstrained platform. Please refer to Table 7-2 for discrete points that constitute the thermal profile.
2. Implementation of the Frequency Optimized Server/Workstation Processor Thermal Profile should result in
virtually no TCC activation. Furthermore, utilization of thermal solutions that do not meet the thermal
profile will result in increased probability of TCC activation and may incur measurable performance loss.
3. Refer to the Intel® Xeon® Processor 5500/5600 Series Thermal/Mechanical Design Guidelines for system
and environmental implementation details.
Figure 7-1. Frequency Optimized Server/Workstation Platform Thermal Profile (6 Core)
40
45
50
55
60
65
70
75
80
85
0 10 20 30 40 50 60 70 80 90 100 110 120 130
Power [W]
Temperature [C]
Y = 0.176 *x + 55.6
40
45
50
55
60
65
70
75
80
85
0 10 20 30 40 50 60 70 80 90 100 110 120 130
Power [W]
Temperature [C]
Y = 0.176 *x + 55.6
Table 7-2. Frequency Optimized Server/Workstation Platform Thermal Profile (6 Core)
Power (W) Maximum T
CASE
(C)
0 55.6
10 57.4
20 59.1
30 60.9
40 62.7
50 64.4
60 66.2
70 67.9
80 69.7
90 71.5
100 73.2
110 75.0
120 76.8
130 78.5