Datasheet

QLogic 12800 InfiniBand Switches for the IBM Intelligent Cluste
r
2
Part number information
Table 1 shows the part numbers to order these modules and additional options for them.
Table 1. IBM part numbers for ordering
Description IBM part number
QLogic 12800-180 QDR InfiniBand Switch Bundle 0449-022
QLogic 12800-360 QDR InfiniBand Switch Bundle 0449-023
QLogic 12800 QDR Single Spine Module 0449-024
QLogic 12800 QDR Double Spine Module 0449-025
QLogic 12800 Management Module 49Y8543
QLogic 12800 24-port 4X QDR Ultra-HD InfiniBand Leaf Module 0449-026
QLogic 12800 18-port 4X QDR Ultra-HP InfiniBand Leaf Module 0449-027
QLogic 12800 Hot-swap Power Supply 49Y8504
The QLogic 12800-180 and 12800-360 QDR InfiniBand director switches, based on QLogic TrueScale
ASIC technology, deliver the next evolution in switch fabric performance for High Performance Computing
(HPC) environments.
These switches deliver high port density and low power per port:
The 12800-180 provides 324 QDR ports using 18-port Ultra-High Performance (UHP) leaf modules or
432 QDR/DDR ports using 24-port Ultra-High Density (UHD) leaf modules in a 14U chassis.
The 12800-360 provides 648 QDR ports using 18-port Ultra-High Performance (UHP) leaf modules or
864 QDR/DDR ports using 24-port Ultra-High Density (UHD) leaf modules in a 29U chassis.
The high-availability 12800 design includes hot swappable InfiniBand spine and leaf modules, fully
redundant power and cooling, and redundant management processors supporting chassis management
(CLI and GUI), as well as embedded InfiniBand Subnet Managers (SMs). The 12800 also supports
advanced QLogic fabric features including adaptive routing, Virtual Fabrics (vFabric), Quality of Service
(QoS), and management wizards for automated installation, configuration, and monitoring to maximize
operational efficiency.
Benefits
The QLogic 12800 InfiniBand switch offers the following benefits:
Low Latency: The QLogic 12800 provides scalable, predictable low latency, even at 90% traffic use.
Predictable latency means HPC applications can be scaled easily without worrying about diminished
cluster performance or costly system tuning efforts.
Flexible Partitioning: The QLogic 12800 advanced design is based on an architecture that provides
comprehensive virtual fabric partitioning capabilities that enable the InfiniBand fabric to support the
evolving requirements of an organization. The TrueScale architecture, together with IFS, allows the
fabric to be shared by mission critical applications while delivering maximum bandwidth utilization.