Datasheet
4
IBM Systems and Technology Group
Data Sheet
Input
Nominal input voltage 100/120 V 230 V
Input frequency (autosensing) 50/60 Hz +/- 3 Hz
Input connection type IEC 320 C20 IEC 320 C14
Input cords IEC 320 C19 to NEMA 5-20P 4.3 m Optional Country Specific Line Cords
Input voltage range, mains 84 - 121 V for 100 V 160 - 286 V for 230 V
operations 97 - 145 V for 120 V
Batteries
Typical backup times 14 minutes (@ 50% rated W)
5 minutes (@ rated W)
Battery type Valve Regulated Lead Acid (VRLA)—Maintenance free, sealed, leak proof
Optional external battery pack Yes
Typical recharge time 4 hours to 90% charge from a UPS/battery discharge of 50% rated load
Communications and management
Interface port USB HID Port/Serial/Optional LAN Card
Management software included Intelligent power manager supervisory software
Control panel Intelligent three-button, dual-color, backlit graphical LCD displays vital UPS status in nine languages
Audible alarm Alarm when on battery: Distinctive low-battery alarm
Remote Power Off (REPO) REPO port
Surge protection and filtering
Surge energy rating 1200J 2400J
Filtering ANSI/IEEE C62.41; 1991 CATEGORYB3 (SURGE)
Physical
Rack height 2U
Dimensions (H x W x D) 3.3 x 17.2 x 22.8 in./84.5 x 438x 579.2 mm
Product weight 68 lb/31 kg
Packaging weight 41 kg
Color IBM Black Bezel
Environmental and Safety
Audible noise, 1 meter from
Normal operation at rated load and Battery Discharge Mode <55 dbA
unit surface
For load <70% <50 dbA
Efficiency 95% minimum at full-rated load—normal usage, not during battery recharge
Operating Temperature 0°C (32°F) to +40°C (104°F)
Relative Humidity 0 - 95% noncondensing
Safety Markings UL, cUL; IEC/EN 62040-1-1, IEC/EN 60950-1, TUV CB Report; CE Mark, TUV CB Report transfer global
EMC Markings 100/120 V: FCC Class B, EN55022 Class B; BSMI, CNS14757-2, Class B
230 V: CE (per IEC/EN62040-2: Emissions, Category C1; Immunity, Category C2); VCCI, Class B; C-Tick,