Datasheet

8068ch08-Storage Pools.fm Draft Document for Review January 29, 2013 12:52 pm
330 IBM Flex System V7000 Storage Node Introduction and Implementation Guide
Figure 8-48 Select a drive to swap out of the MDisk
In Figure 8-49, select an available Candidate or Spare drive to swap into the Array MDisk
and click Finish.
Figure 8-49 Select a drive to swap into the MDisk
The exchange of the drives starts and runs in the background, and the volumes on the
affected MDisk remain accessible.
򐂰 Delete: An Array MDisk can be deleted by clicking RAID Actions Delete. A
confirmation of the deletion by entering the correct number of MDisks to be deleted is
required (Figure 8-50 on page 331). You need to confirm the number of array MDisks you
want to delete. If there is data on the MDisk, it can be deleted only by checking the item
Delete the RAID array MDisk even if it has data on it. The system migrates the data
to other MDisks in the pool.