Datasheet
If you are instructed to return a component, follow all packaging instructions, and
use any packaging materials for shipping that are supplied to you.
Table 4 lists the replaceable components.
Table 4. CRU list
Description Tier 1 CRU part number
Internal RDX USB drive 46C5380
External RDX USB drive 46C5381
RDX 160 GB cartridge 46C5393
RDX 320 GB cartridge 46C5394
RDX 500 GB cartridge 46C5395
System x3650 or x3655 internal USB cable 46M6475
System x3400 or x3500 internal USB cable 46M6477
System x3105 or x3200 internal USB cable 44E8885
1 M internal USB cable for all other System x
servers
44E8893
External RDX power adaptor 46C5385
3.5-inch bezel 46C5392
Mounting screws 42C3933
To remove the internal RDX drive, complete the following steps:
1. Read the safety information that begins on page v and “Handling static-sensitive
devices” on page 5.
2. Make sure that the server is turned off and that the power cord is disconnected.
3. Remove the cartridge from the drive.
4. Remove the server covers, using the instructions that came with the server.
5. Disconnect the power cord from the drive.
6. Disconnect the USB cable from the drive.
7. Remove the drive from the bay, using the drive-installation instructions that
came with your server.
Chapter 3. Using the RDX drive 13