Datasheet
Operation
Green
Ready
Amber
Fault
Single
Character
Display
(SCD)
Response
Power-On
Self-Test in
progress.
Off Off or On(3) Segments
flashing(1)
Wait 30 to 60 seconds.
After Power-
On Self-Test
and the drive
resets(2).
3 seconds On
(2)
3 seconds On
(2)
3 seconds On
(2)
Wait 30 to 60 seconds.
No Cartridge
is Loaded.
Off Off or On(3) Off or C (3) Wait 30 to 60 seconds.
Cartridge is
Loading or
Unloading
Flashing(1) Off or On(3) Off or C (3) Wait 30 to 60 seconds.
Cartridge is
Loaded, No
Activity
On Off or On(3) Off or C (3) Wait 30 to 60 seconds.
Data Cartridge
is Loaded,
Activity
Flashing(1) Off or On(3) Off or C (3) Wait 30 to 60 seconds.
Cleaning is
Required
On or Off On(3) C (3) Clean drive as soon as possible
Cleaning in
Progress
Flashing Off C (3) Wait for Cleaning to complete.
Cleaning
Cartridge
Loaded,
Cleaning
Failed
Off On 6 or 7(4) Replace Cleaning Cartridge, which may be expired.
Maximum
Operating
Temperature
Exceeded(5).
Off On 1 Reduce Drive Temperature.
Input Voltage
Failure
Off On 2 Check Input Power Connectors.
Drive
Firmware
Failure
Off Flashing(1) 3 Update to Latest Level of Firmware.
Drive
Firmware or
Hardware
Failure
Off Flashing(1) 4 Clean Drive, Replace Cartridge, or both, if needed, Retry
Operation.
Unrecoverable
Drive Failure
Off Flashing(1) 5 Clean Drive, Replace Cartridge, or both, if needed, Retry
Operation.
Drive or
Media Failure
(7)
Off On 6 Clean Drive, Replace Cartridge, or both, if needed, Retry
Operation.
Media Error Off On 7(4) Replace Cartridge, Possible Expired Cleaning Cartridge.
SAS Interface
Failure.
Off Flashing(1) 8 Check SAS Cable and Connector.
Recoverable
Drive Error(8)
Off On A Clean the Drive and Retry the Operation.
Page 30 of 93Tape Help Package
5/20/2008file://C:\tem
p
\TAPEWHDR.html