1. A solid amber Cleaning LED indicates that the drive needs cleaning. The drive will continue to function but needs
cleaning as soon as possible. Do not ignore the indicator by cycling the power to turn it off.
2. The media has reached the end of its useful life and should be replaced. Any data should be copied to a new cartridge
as soon as possible.
3. Flashing in this state indicates a problem with write/read performance.
4. An unrecoverable drive failure is an error condition that results in the drive not being able to function unless initiator,
operator, or service intervention is applied.
An unrecoverable drive failure is usually the result of a hardware error condition.
One of the following actions is needed to clear the flashing fault LED:
{ Hard SCSI reset
{ Cartridge emergency eject
{ Power cycle
{ Retry firmware download
An unrecoverable media failure is usually the result of a defective cartridge, media, or cartridge state, and will require
the drive to eject the cartridge (if possible) to clear the On LED.
Off Off (3) or
Off
Data Cartridge Unloading On(1) or
Off
On(2) or
Off
Flashing
(3) or
Off
Flashing
Data Cartridge Ejected On(1) or
Off
On(2) or
Off
Flashing
(3) or
Off
Off
Cleaning Cartidge Loaded, Activity On Off Flashing
(3) or
Off
Flashing
Cleaning Succeeded, Cleaning Cartridge Ejected Off Off Flashing
(3) or
Off
Off
Cleaning Failed, Cleaning Cartridge Ejected On(1) On Flashing
(3) or
Off
Off
Unrecoverable Drive Failure(4) On(1) On Flashing Flashing
Unrecoverable Media Failure(4) On(1) On Off Flashing, On,
or Off
Firmware Download: Download and reprogram Flashing Off Off Flashing
Firmware Download: Possible Unload (See Data Cartridge Unloading)
Firmware Download: Reset in 1 second. On On On On
Firmware Download: Self Test (See Power on Self-Test Activity, and then
see either POST Passed or POST Failed.)
Firmware Download: Reprogram Failure Off Off Flashing Off
SCSI diagnostic test in progress (See Data Cartidge Loaded, Activity)
SCSI diagnostic test passed (See Data Cartidge Loaded, No Activity)
Scsi diagnostics test failed, tape ejected (After Data Cartridge Ejects, see
Data Cartridge Ejected.
On On On Flashing
Tape Diagnostics in Progress (See Data Cartrtridge Loaded and then:) Flashing Off Off Flashing
Tape Diagnostics in Passed, Tape Ejected (After Data Cartidge ejects, see
Data Cartridge Ejected.
Off Off Off Flashing
Tape Diagnostics in Failed, Tape Ejected (After Data Cartidge ejects, see
Data Cartridge Ejected.
On On On Flashing