Datasheet

IBM United States Hardware Announcement 113-198 IBM is a registered trademark of International Business Machines Corporation
28
Electrical
IBM Flex System x240 Compute Node: 12.2 (nominal) V dc
Note: All weights and measurements are approximate.
Standards
Equipment approvals and safety
FCC - Verified to comply with Part 15 of the FCC Rules Class A
Canada ICES-004, issue 3 Class A
UL/IEC 60950-1
CSA C22.2 No. 60950-1
NOM-019
Argentina IEC 60950-1
Operating environment
The IBM Flex System x240 compute node complies with ASHRAE Class A3
specifications.
Power on:
Temperature: 5°C to 40°C (41°F to 104°F)
Humidity, noncondensing: -12°C dew point (10.4°F) and 8% - 85% relative
humidity
Maximum dew point: 24°C (75°F)
Maximum altitude: 3,048 m (10,000 ft)
Maximum rate of temperature change: 5°C/hr (41°F/hr)
Power off:
Temperature: 5°C to 45°C (41°F to 113°F)
Relative humidity: 8% - 85%
Maximum dew point: 27°C (80.6°F)
Storage (non-operating):
Temperature: 1°C to 60°C (33.8°F - 140°F)
Altitude: 3,050 m (10,006 ft)
Relative humidity: 5% - 80%
Maximum dew point: 29°C (84.2°F)
Shipment (non-operating):
Temperature: -40°C to 60°C (-40°F - 140°F)
Altitude: 10,700 m (35,105 ft)
Relative humidity: 5% - 100%
Maximum dew point: 29°C (84.2°F)
Particulate contamination
Hardware requirements
For service, the IBM Flex System x240 Compute Node requires a compatible:
Monitor
Combination USB keyboard and pointing device such as IBM part number
40K5372
USB CD-RW/DVD drive such as the IBM and Lenovo part number 73P4515 or
73P4516