Network Card User Manual

Table 4. Warning remote alerts
Alphanumeric
pager code
Event Action
10 Redundant power
supply failure
Generates an alert if a redundant power supply fails.
11 Single fan failure Generates an alert if one fan fails.
12 Temperature irregularity Generates an alert if any monitored temperatures are outside the
warning threshold values. To access these temperature threshold values,
click the temperature readings on the System Health page. Unlike the
critical temperature event, this event will not initiate a server shutdown.
13 Voltage irregularity Generates an alert if any monitored voltages are outside the warning
threshold values. To access these voltage range values, click the voltage
readings on the System Health page. Unlike the critical voltage event,
this event will not initiate an automatic server shutdown.
14 - 19 Reserved for future use.
System alerts
System alerts are generated for events that occur as a result of system
errors. If the Select all system alerts check box is selected, an alert
can be sent for any system alert.
Notes:
a. The Select all system alerts check box is not available on all
servers.
b. Hard disk drive Predictive Failure Analysis
®
(PFA) alerts are not
monitored.
Table 5. System remote alerts
Alphanumeric
pager code
Event Action
20 POST timeout Generates an alert if an enabled POST timeout value is exceeded. The
POST timeout value is configured in the Server Timeouts section on the
System page.
21 O/S timeout Generates an alert if an enabled operating system timeout value is
exceeded. The operating system timeout value is configured in the
Server Timeouts section on the System page. The O/S timeout alert
must be checked to enable remote blue screen capture.
22 Test alert Generates an alert if the Generate Test Alert button is clicked on the
Remote Alert Recipients page.
23 Power off Generates an alert if the server is turned off.
24 Power on Generates an alert if the server is turned on.
25 Boot failure Generates an alert if an error occurs that prevents the server from
starting.
26 Loader timeout Generates an alert if an enabled server loader timeout value is
exceeded. The system loader timeout value is configured in the Server
Timeouts section on the System page.
27 PFA notification Generates an alert if a PFA notification is generated by the server
hardware. This feature is available only on server that have PFA-enabled
hardware.
28 - 29 Reserved for future use.
5. Scroll to the bottom of the page and click Save.
28 Remote Supervisor Adapter: User’s Guide