- IBM switch Users and Maintenance Guide

v Do not overtighten the cable straps or bend the cables to a radius of less than 38
mm (1.5 in.).
v Do not put excess weight on the cable at the connection point. Be sure that the
cable is well supported.
Installing SFP modules
The DS4100 host ports require SFP modules. SFP modules are used to convert
electrical signals to optical signals that are required for fibre channel transmission to
and from RAID controllers. The DS4100 supports two types of SFP modules: one
with a plastic latch and one with a wire latch. After you install the SFP modules, you
use fiber-optic cables to connect the DS4100 to other fibre channel devices.
Before you install SFP modules and fiber-optic cables, read the following
information:
v Do not mix long-wave SFPs and short-wave SFPs on a single storage server.
Use either long-wave SFPs or short-wave SFPs. You can use the DS4000
Storage Manager client to view the storage subsystem profile in order to verify
that you are not mixing long-wave and short-wave SFPs.
v The SFP module housing has an integral guide key designed to prevent you from
inserting the SFP module improperly.
v Use minimal pressure when you insert the SFP module into a port. Forcing the
SFP module into a port could cause damage to the SFP module or the port.
v You can insert or remove the SFP module while the port is powered on.
v The operational loop performance is not affected when you install or remove an
SFP module.
v You must insert the SFP module into a port before you connect the fiber-optic
cable.
v You must remove the fiber-optic cable from the SFP module before you remove
the SFP module from the port. See “Removing SFP modules” on page 48 for
more information.
To
install an SFP module, complete the following steps.
Statement 3:
CAUTION:
When laser products (such as CD-ROMs, DVD drives, fiber-optic devices, or
transmitters) are installed, note the following:
v Do not remove the covers. Removing the covers of the laser product could
result in exposure to hazardous laser radiation. There are no serviceable
parts inside the device.
v Use of controls or adjustments or performance of procedures other than
those specified herein might result in hazardous radiation exposure.
46 IBM TotalStorage DS4100 Storage Server: Installation, Users, and Maintenance Guide