Setting requirement
A: Required (function selection)
B: Required (network environment, etc.)
C: Checked (As a rule, the default value
on the parameter list must be used.)
Modbus/
TCP
IAI protocol
B/TCP
Transmission by
SEL program
No. Parameter name
Default value
(reference)
Input range Unit Remarks
B B B
133
Own IP address
(MH)
168 0~255
B B B
134
Own IP address
(ML)
0 0~255
B B B
135 Own IP address (L) 1 1~254
* Setting of “0” and “255” is prohibited.
B B B
136 Subnet mask (H) 255 0~255
B B B
137 Subnet mask (MH) 255 0~255
B B B
138 Subnet mask (ML) 255 0~255
B B B
139 Subnet mask (L) 0 0~255
B B B
140 Default gateway (H) 0 0~255
B B B
141
Default gateway
(MH)
0 0~255
B B B
142
Default gateway
(ML)
0 0~255
B B B
143 Default gateway (L) 0 0~255
C 144
IAI protocol B/TCP:
Own port number
(MANU mode)
64511 1025~65535
C 145
User-open channel
31 (TCP/IP): Own
port number
64512 1025~65535
C 146
User-open channel
32 (TCP/IP): Own
port number
64513 1025~65535
C 147
User-open channel
33 (TCP/IP): Own
port number
64514 1025~65535
C 148
User-open channel
34 (TCP/IP): Own
port number
64515 1025~65535
* Important note: Be sure to set a unique number for each