(In the panel window, the three digits after “E” indicate an error number.)
Error No. Error name Description, action, etc.
EAC Servo control underrun error A servo control underrun error was detected.
EAD Boot error A FPGA boot watchdog was detected. The core program may not be
running properly.
EAE Application-update SCIF receive-queue overflow error Excessive data is received from outside. (Confirm that a PC and IAI’s
update tool are used to update the application.)
EAF Installed flash ROM type mismatch (Core) The flash ROM type anticipated in the software does not match the flash
ROM type actually installed. Check the combination of software and
hardware.
EB2 Flash busy reset timeout (Detected by the core) Malfunction of the flash ROM. The flash ROM is not reset from the busy
mode.