Owner manual

341
INTELLIGENT ACTUATOR
Appendix
Appendix
(In the panel window, the three digits after ā€œEā€ indicate an error number.)
Error No. Error name Description, action, etc.
E81 Priority auto-assignment card non-detection error Priority auto-assignment card cannot be detected.
E82 Card mismatch error The combination or positioning of I/O slot cards has a problem.
E83 I/O slot card error The I/O slot card is invalid.
E84 Resolution parameter error Check axis-specific parameter Nos. 47, 50, 51, 44, 42, 43, 1, 37, etc.
E85 Driver ready OFF factor indeterminable error Driver ready OFF factor cannot be determined.
E86 Fieldbus error (FBVCCER) A fieldbus error (FBVCCER) was detected.
E87 Fieldbus error (FBPOWER) A fieldbus error (FBPOWER) was detected.
E88 Power error (Other) A power error (Other) was detected. This error also generates when the
power OFF o ON interval is short. After the power has been turned off, be
sure to wait for at least 5 seconds before turning it back on. Abnormal
regenerative resistance temperature is also suspected.
E89 SCIF open error in non-AUTO mode (Servo in use) In a mode other than AUTO, opening of the serial 1 channel (also used by
the PC software/TP port) from a SEL program is prohibited while the servo
is in use (to ensure safety).
E8A SEL program flash-ROM status error Data is not written to the flash ROM correctly or written in an old,
incompatible application version.
E8B Symbol definition table flash-ROM status error Data is not written to the flash ROM correctly or written in an old,
incompatible application version.
E8C Point data flash-ROM status error Data is not written to the flash ROM correctly or written in an old,
incompatible application version.
E8D Parameter flash-ROM status error Data is not written to the flash ROM correctly or written in an old,
incompatible application version.
FF0 to
F00
Shutdown error (hi_sysdwn () definition) A shutdown error (hi_sysdwn () definition) was detected.
F03 to
F58
Shutdown error (OS call error) A shutdown error (OS call error) was detected.
F60 System-down level error-call procedure error A system-down level error-call procedure error was detected.
F61 Interpreter-task end task ID error An interpreter-task end task ID error was detected.
F62 Abnormal standby power detection error Abnormal standby power was detected.
F63 Regenerative resistance temperature error A regenerative resistance temperature error was detected.
F64 AC-power overvoltage error An AC-power overvoltage error was detected.
F65 Motor-power overvoltage error A motor-power overvoltage error was detected.
F66 Servo control underrun error A servo control underrun error was detected.
F67 FROM-write bus width error A write operation other than 32-bit long word access was detected while
writing the flash ROM.