1. I/O Parameters
No. Parameter name
Default value
(Reference)
Input range Unit Remarks
1 I/O port assignment
type
0 Reference only 0: Fixed assignment
2 Input port start number
with fixed standard I/O1
assignments
000 -1 to 599 0 + (Multiple of 8) (Invalid if a negative value is set)
* Keep the default value if the main application version is
0.18 or earlier.
(Change prohibited)
3 Output port start
number with fixed
standard I/O1
assignments
300 -1 to 599 300 + (Multiple of 8) (Invalid if a negative value is set)
* Keep the default value if the main application version is
0.18 or earlier.
(Change prohibited)
4 Input port start number
with fixed expanded
I/O2 assignments
32 -1 to 599 0 + (Multiple of 8) (Invalid if a negative value is set)
* Keep the default value if the main application version is
0.18 or earlier.
(Change prohibited)
5 Output port start
number with fixed
expanded I/O2
assignments
316 -1 to 599 300 + (Multiple of 8) (Invalid if a negative value is set)
* Keep the default value if the main application version is
0.18 or earlier.
(Change prohibited)
6 Input port start number
with fixed expanded
I/O1 assignments
(Network I/F module)
-1 -1 to 599 0 + (Multiple of 8) (Invalid if a negative value is set)
7 Output port start
number with fixed
expanded I/O1
assignments (Network
I/F module)
-1 -1 to 599 300 + (Multiple of 8) (Invalid if a negative value is set)
8 For future expansion -1 -1 to 599
9 For future expansion -1 -1 to 599
10 Standard I/O1 error
monitor
1 0 to 5 0: Do not monitor
1: Monitor
2: Monitor (Do not monitor errors relating to 24-V I/O power
source)
3: Monitor (Monitor only errors relating to 24-V I/O power
source)
* Some exceptions apply.
11 Expanded I/O2 error
monitor
1 0 to 5 0: Do not monitor
1: Monitor
2: Monitor (Do not monitor errors relating to 24-V I/O power
source)
3: Monitor (Monitor only errors relating to 24-V I/O power
source)
* Some exceptions apply.
12 Expanded I/O1 error
monitor (Network I/F
module)
1 0 to 5 0: Do not monitor
1: Monitor
* Some exceptions apply.
13 For future expansion 1 0 to 5
14 Number of ports using
network-I/F-module
remote input
0 0 to 240 Refer to the operation manual for each network I/F card
(CC-Link, DeviceNet, etc.).
15 Number of ports using
network-I/F-module
remote input
0 0 to 240 Refer to the operation manual for each network I/F card
(CC-Link, DeviceNet, etc.).
16 (For future expansion =
Change prohibited)
0 0 to 256 Multiple of 8
17 (For future expansion =
Change prohibited)
0 0 to 256 Multiple of 8
18 to
19
(For expansion) 0
20 Input filtering periods 2 1 to 9 msec Input signal is recognized when the status is held for twice
the period set by this parameter.
21 Register input filtering
periods
2 1 to 9 msec Input signal is recognized when the status is held for twice
the period set by this parameter.
22 For future expansion 2000 Reference only msec