Owner manual

268
INTELLIGENT ACTUATOR
Appendix
Appendix
18. Moving to a Specified Position Number
Description
Read an external BCD code input as a position number and cause the actuator to move to the
corresponding position.
Example of Use
Use an INB command to read a BCD code from an input port as a position number. Up to three digits
can be specified as a position number.
Input assignments Output
Port Description 303 Completion of movement
28 Start input
16 Position specification 1
17 Position specification 2
18 Position specification 4
19 Position specification 8
20 Position specification 10
21 Position specification 20
22 Position specification 40
23 Position specification 80
24 Position specification 100
25 Position specification 200
26 Position specification 400
27 Position specification 800
Application program
Flowchart
Start
Initial setting
Start input
BDC is read
Movement
completion OFF
Move to the
specified position
number
Movement
completion ON