Owner's manual

210210210
15. Monitor
210
15.10. Maintenance Information Window
This mode displays the number of actuator movement and distance.
It displays as XSEL-R/S, RX/SX, RXD/SXD controller.
3UHVV)NH\0QW,LQWKHPRQLWRUZLQGRZ
7KHQ3UHVV)NH\$[LV
Mode Transfer: Moni - MntI - Axis
6HOHFWWKH$[LV1RXVLQJWKH3$*(833$*('2:1NH\
The selected Axis No. will be displayed in the Axis No. Display Section.
3UHVV)%DFNRU)1H[WWRVHOHFWRQHRIWKHIROORZLQJLWHPV
The data will be displayed in the Data Display/Editing Section.
No. Item Indication Description
1 Total number of movement TtlMovCnt Displays the total No. of actuator
movement times.
2 Total Movement Count
Threshold
TtlMovCntThrshld Displays the threshold value of the total
movement times.
3 Total driving distance [m] TtlMil Displays the total distance (m) of the
actuator movement.
4 Total Operated Distance
Threshold [m]
TtlMilThrshld Displays the threshold value of the total
travel distance.
The values of “Total Movement Count Threshold” and “Total Operated Distance Threshold [m]”
can be edited.
,QSXWWKHQXPHULFDOYDOXHXVLQJWKHWHQNH\SDGDQGSUHVVWKHUHWXUQNH\
$IWHUWKHGDWDLVHQWHUHGWUDQVIHUWKHGDWDWRWKHFRQWUROOHUXVLQJWKH:57NH\
When the data has been written, and the previous window is returned from the axis associated
PDLQWHQDQFHLQIRUPDWLRQZLQGRZXVLQJWKH(6&NH\WKH)ODVK520GDWDLPSRUWDQGVRIWZDUH
UHVHWDUHFRQ¿UPHG
,QRUGHUWRDSSO\WKHZULWWHQGDWDLPSRUWWKHGDWDRQWKHÀDVK520DQGUHVHWWKHVRIWZDUH
(Note) In the case that the Axis No. or item is changed without importing the data, the input
data is erased.
Ԙ
ԙ
Ԛ
Data Title Display Section
Data Display/Edit Section
Function Key Display Section
Axis No. Display Section