Manual
31
3. Installation and Wiring
3.10 Connecting the I/O Flat Cable
Signal name
No.
Proximity switch type Standard type
Color Wiring
1 24 V Brown-1
2 0 V Red-1
3 Rear end move command input Rear end move command Orange-1
4 Front end move command input Front end move command Yellow-1
5
Intermediate point move command
input
Intermediate point move command Green-1
6 Servo-on command input Servo-on command input Blue-1
7 Rear end detection output Rear end positioning complete output Purple-1
8 Front end detection output
Front end positioning complete
output
Gray-1
9 Intermediate point detection output
Intermediate point positioning
complete output
White-1
10 Ready output Zone output Black-1
11 Homing complete output Homing complete output Brown-2
12 Alarm output Alarm output Red-2
Flat cable
(pressure-
welded)
Warning: When checking the continuity of the flat cable, exercise due caution not to bend the female pins on the
connector outward. It may cause contact failure, resulting in malfunction.
Red 2
Brown 1
Cable type:
Housing:
Contact: