Owner manual

Table Of Contents
8. External Dimensions
57
8.1.3 Horizontally Oriented Wall Mount Type (Cable Track Opposite Type)
(Option)
S6SS Horizontally Oriented Wall Mount Type (Cable Track Opposite Type) (Option)
No. st L A B C D Weight (kg)
1 48 334 1 28 8 128 3.6
2 96 382 1 76 8 176 3.8
3 144 430 1 124 8 224 4.0
4 192 478 1 172 8 272 4.2
5 240 526 2 20 12 320 4.4
6 288 574 2 68 12 368 4.6
7 336 622 2 116 12 416 4.8
8 384 670 2 164 12 464 5.0
9 432 718 3 12 16 512 5.2
10 480 766 3 60 16 560 5.5
11 528 814 3 108 16 608 5.7
12 576 862 3 156 16 656 5.9
13 624 910 3 204 16 704 6.1
14 672 958 4 52 20 752 6.3
15 720 1006 4 100 20 800 6.5
16 768 1054 4 148 20 848 6.7
17 816 1102 4 196 20 896 6.9
18 864 1150 5 44 24 944 7.1
19 912 1198 5 92 24 992 7.3
20 960 1246 5 140 24 1040 7.5
21 1008 1294 5 188 24 1088 7.8
22 1056 1342 6 36 28 1136 8.0
23 1104 1390 6 84 28 1184 8.2
24 1152 1438 6 132 28 1232 8.4
25 1200 1486 6 180 28 1280 8.6
26 1248 1534 7 28 32 1328 8.8
24
15
14
19
19
14
40
49
1 24
5.5
2.71.8
5.8
3.3
60
ME
SE
155
90
89
51
91
4
60
54
81.5
76.5
43
(35)5
5
63 63st
84
4
*The slider goes up the ME in the home-return operation.
Pay attention to interference to peripherals.
ME : Mechanical end
SE : Stroke end
Cable track for user
(M type)
Cable track for user
(S type)
Detail view of G
Detail view of F
+0.01
0
3
M3 T-slot
(F)
Cable Track for User Wiring
Section Dimensions (S type)
Cable Track for User Wiring
Section Dimensions (M type)
Cable
35
50
(B)
50
30
A×100
P
A×100
P
2-
φ
3H7,
reamed depth 3
2-slot,
depth 3 (G)
C-M4, depth 10
D
L(st+286)
160
50
80
25
88 37
65±0.02
4-M4, depth 10
2-
φ
4H7, depth 8
(Reamer pitch: ±0.02)
45
25
ME (*)
(35)
HOME
35