Owner manual
2. Installation
37
[Load and Offset]
٧PTP Operation
In the case that the actuator is moved with a transfer load of 10kg or less and a speed of 50% or
less, set the load offset to 70mm or less as shown in the following graph. When the speed is at
50%, the load offset is 70mm no matter what the transported load weight is.
0
10
20
30
40
50
60
70
0 10 20 30 40 50
Transported Load [kg]
Load Offset [mm]
Speed 50%
Speed 75%
Speed 100%
٧CP Operation
In the case that the actuator is moved with a transfer load of 20kg or less and a speed of 50% or
less, set the load offset to 70mm or less as shown in the following graph. When the speed is at
50%, the load offset is 70mm no matter what the transported load weight is.
0
10
20
30
40
50
60
70
0 10 20 30 40 50
Transported Load [kg]
Load Offset [mm]
Speed 50%
Speed 75%
Speed 100%