User Manual

26
5. Installation
5.4 Datum Surface and Mounting Surface
x
7KHPRXQWLQJIUDPHVKRXOGKDYHVXI¿FLHQWULJLGLW\WRDYRLGJHQHUDWLRQRIYLEUDWLRQ
x
The surface where the actuator will be mounted should be machined or be equally level, and the
ÀDWQHVVEHWZHHQWKHDFWXDWRUDQGWKHIUDPHVKRXOGEHZLWKLQPP
x
Provide enough space around the actuator so that maintenance work can be carried out.
x
The side and bottom of the actuator base provide reference planes for slider travel.
x
When traveling precision is required, use these surfaces as the reference for mounting.
:KHQLQVWDOOLQJWKHXQLWRQWKHSODWIRUPXVLQJWKHGDWXPVXUIDFHIROORZWKH¿JXUHVKRZQEHORZIRUWKH
SODWIRUPSUR¿OH
As shown in the picture above, the base side surfaces work as the datum for the slider’s run. If
accuracy is required, use these surfaces as a datum for the installation.
Datum SurfaceDatum Surface
Under R0.3
A dimensions (mm)
3 to 5