User Manual

22
5. Installation
5. Installation
Stated below tells how to install the actuator to a mechanical equipment.
5.1 Attachment
This actuator is recommended for a standard horizontal mount for the posture of installation to fully
SHUIRUPLWVGXVWSURRIDQGVSODVKSURRIVSHFL¿FDWLRQV2WKHUSRVWXUHVRILQVWDOODWLRQKRUL]RQWDOZDOO
mount, up-side-down or vertical mount) may allow water to get inside.
5.2 Installing the Main Body
There are tapped holes on the back of the actuator base for installation. Please utilize these holes to
install the unit.
Shown below is the mounting dimension explained in a section.
Machine Type Tap diameter Tap Effective length A
Small Size M6 17mm 70mm
Medium Size M8 20mm 90mm
Large Size M8 20mm 120mm
Bolt to
be used
Tightening Torque
In the case that steel is used for
the bolt seating surface:
In the case that aluminum is used for
the bolt seating surface:
M6 12.3N•m(1.26kg•m) 5.4N•m(0.55kg•m)
M8 30.0N•m(3.06kg•m) 11.5N•m(1.17kg•m)
Surface for screw seat
Screw
Screw-seated surface Screw-seated surface