Owner manual
90
13. Appendix
13. Appendix
Caution: For the external dimensions of ISD/ISDCR/ISPDCR actuators, refer to the catalogs of old
products. You can download the catalogs of old products from IAI’s website.
13.1 External Dimensions
13.1.1 ISDA-S, ISPDA-S
4-M6, depth 13
2-6H7, depth 10
(tolerance for reamed hole pitch r0.02 mm)
Cable joint
connector *1
Home
A
A
t least 100 or more
4-6H7, depth 10
F-M6, depth 17
with brake (option)
T slot diagram ME: Mechanical end
SE: Stroke end
Reference surface
Detail view of A
Dimension, Mass and Maximum Speed by Stroke
Stroke
Weight (kg)
* The brake-equipped type is longer in 24.5mm
and heavier in 0.3kg.